  • Title: Performance of Controlled Attenuation Parameter in Patients with Advanced Chronic Liver Disease and Portal Hypertension.
    Author: Semmler G, Stift J, Scheiner B, Wöran K, Schwabl P, Paternostro R, Bucsics T, Stättermayer AF, Pinter M, Ferlitsch A, Trauner M, Reiberger T, Mandorfer M.
    Journal: Dig Dis Sci; 2019 Dec; 64(12):3642-3651. PubMed ID: 31209721.
    Abstract:
    BACKGROUND: Liver stiffness (LS) measured by vibration-controlled transient elastography (VCTE) is influenced by liver fibrosis and hepatic perfusion pressure. VCTE-based controlled attenuation parameter (CAP) is a noninvasive marker for hepatic steatosis (HS). AIMS: To investigate the diagnostic performance of CAP in patients with advanced chronic liver disease (ACLD)/portal hypertension (PHT: hepatic venous pressure gradient (HVPG) ≥ 6 mmHg). METHODS: Eighty-eight patients with LS ≥ 10 kPa and/or HVPG ≥ 6 mmHg who underwent simultaneous liver biopsy, CAP, and HVPG measurement were included. HS was histologically graded according to the modified Brunt classification. RESULTS: Patient characteristics: Mean MELD:11 (standard derivation [SD] ± 4), median HVPG:16 (interquartile range [IQR]10-19) mmHg, median LS:27.4 (IQR 16.2-48.9) kPa, and mean CAP:221 (SD ± 75) dB/m. According to histology, 47 (53.4%) patients had no HS (S0), 28 (31.8%) had S1, 11 (12.5%) had S2, and 2 (2.3%) had S3. The area under the receiver operating characteristic curve (AUROC) of CAP for diagnosing any HS (S0 vs. ≥ S1) was 0.692 (95% confidence interval [95% CI] 0.582-0.802) in the overall cohort, 0.830 (95% CI 0.637-1.0) in patients with HVPG < 10 mmHg, and 0.629 (95% CI 0.497-0.761) in patients with clinically significant portal hypertension (CSPH; HVPG ≥ 10 mmHg; n = 69). Using the established cutoff for any HS (248 dB/m), the sensitivity/specificity of CAP was only 48.8%/76.6%, respectively. In contrast, the AUROC and sensitivity/specificity (cutoff 268 dB/m) for diagnosing HS ≥ S2 were 0.842 (95% CI 0.747-0.936) and 84.6%/81.3%, respectively. CAP correlated with the percentage of steatotic hepatocytes (Spearman's ρ = 0.402; p ≤ 0.001) and showed a weak correlation with liver stiffness (ρ = 0.225; p = 0.035). CONCLUSIONS: The diagnostic performance of CAP for any HS seems to be limited in patients with ACLD, if CSPH is present.
    [Abstract] [Full Text] [Related] [New Search]