These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Size and Shape of Bruch's Membrane Opening in Relationship to Axial Length, Gamma Zone, and Macular Bruch's Membrane Defects. Author: Zhang Q, Xu L, Wei WB, Wang YX, Jonas JB. Journal: Invest Ophthalmol Vis Sci; 2019 Jun 03; 60(7):2591-2598. PubMed ID: 31219533. Abstract: PURPOSE: To assess axial elongation-associated characteristics in Bruch's membrane opening (BMO) as the inner optic nerve head lamella. METHODS: Participants of the population-based Beijing Eye Study without glaucoma underwent optical coherence tomography for measurement of the BMO size and shape. RESULTS: The study included 365 individuals (mean age, 61.0 ± 8.7 years; range, 50-88 years; axial length, 24.45 ± 1.99 mm; range, 21.32-30.88 mm). Larger horizontal (mean:1.62 ± 0.28 mm) and vertical (mean: 1.74 ± 0.27 mm) BMO diameters were linearly associated with longer axial length beyond an axial length of 26.0 mm (horizontal diameter: P < 0.001; standardized regression coefficient β: 0.66; nonstandardized regression coefficient B: 0.22; 95% confidence interval (CI): 0.16, 0.27; vertical diameter: P < 0.001; β: 40; B: 0.12; 95% CI: 0.06, 0.18). In multivariable analysis, wider largest gamma zone was associated with larger intrapapillary Bruch's membrane (BM) overhanging on the side opposite to the largest gamma zone (P = 0.006; β: 0.14; B: 0.35; 95% CI: 0.10, 0.60) and with longer horizontal BMO diameter (P < 0.001; β: 0.46; B: 0.59; 95% CI: 0.46, 0.73). The widest BM overhanging location (superior to nasal) was inversely correlated with the widest gamma zone location (inferior to temporal). Within the axial length group of ≥28.0 mm, eyes with macular BM defects had a less markedly increased BMO than those without macular BM defects (2.27 ± 0.18 vs. 2.71 ± 0.41 mm; P = 0.019). The difference between horizontal BMO diameter minus horizontal gamma zone width decreased (P < 0.001) with longer axial length. CONCLUSIONS: Beyond 26.0 mm of axial length, horizontal and vertical BMO diameter increased by 0.21 mm (95% CI: 0.16, 0.27) and 0.12 mm (95% CI: 0.06, 0.18), respectively, for each millimeter of axial elongation. Gamma zone may develop due to an axial elongation-associated BMO enlargement (β: 0.46) and, to a minor degree, a BMO shift in direction to the macula (β: 0.14). A large gamma zone may be protective against myopic macular BM defects.[Abstract] [Full Text] [Related] [New Search]