These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Transtracheal jet oxygenation: Comparing the efficacy and safety of two self-made Y-connector devices with the ENK oxygen flow modulator™ in an infant animal model. Author: Lim EHL, Tan AYJ, Sng DDW, Saffari SE, Tan JSK. Journal: Paediatr Anaesth; 2019 Aug; 29(8):799-807. PubMed ID: 31233654. Abstract: BACKGROUND: Self-made Y-connector jet-oxygenation devices with wide-bore expiratory port have been described but not evaluated in infant models. Little is known about the effect of oxygen flow rates on jet oxygenation via transtracheal cannula. AIMS: The aim of this study was to compare two self-made Y-connector jet-oxygenation devices against the ENK oxygen flow modulator™, and the effects of three different oxygen flow rates based on body weight, in both unobstructed and obstructed airways, on the time to re-oxygenate in a rabbit infant model. The aim was also to assess the effectiveness of an oxygen flow rate of 1 L/min, for re-oxygenation using ENK oxygen flow modulator™. METHODS: Nine rabbits were grouped in threes: Group 1 had a Y-connector attached to an intravenous infusion tubing, Group 2 the same Y-connector attached to a perfusion oxygenator tubing and Group 3, ENK oxygen flow modulator™. From oxygen saturations of 75%, the rabbits were jet oxygenated using their assigned device for 10 minutes at each flow rate of 1 L/kg/min, 1.5 L/kg/min and 2 L/kg/min with their airways unobstructed and later, obstructed. Group 3 had additional experiments involving an absolute oxygen flow rate of 1 L/min. RESULTS: All devices resulted in rapid re-oxygenation within 40 seconds at flow rates of 1 L/kg/min. Oxygen flow rates beyond 1 L/kg/min in obstructed airways resulted in high airway pressures. All rabbits in Group 3 with obstructed airways died from barotrauma when jet oxygenated at a flow rate of 1.5 L/kg/min. When an oxygen flow rate of 1 L/min was used in Group 3, there was a failure to re-oxygenate to SpO2 90% within 120 seconds in some rabbits. CONCLUSION: Our animal model results suggest that self-made Y-connector jet-oxygenation devices with wide-bore expiratory port are efficacious and perhaps safer than ENK oxygen flow modulator™ in obstructed airways, and jet oxygenation with minimal oxygen flow rates starting at 1 L/kg/min or (age [years] + 4) L/min, whichever lower, should be considered.[Abstract] [Full Text] [Related] [New Search]