These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A comparative analysis of 3MAX aspiration versus 3 mm Trevo Retriever for distal occlusion thrombectomy in acute stroke. Author: Haussen DC, Eby B, Al-Bayati AR, Grossberg JA, Rodrigues GM, Frankel MR, Nogueira RG. Journal: J Neurointerv Surg; 2020 Mar; 12(3):279-282. PubMed ID: 31243066. Abstract: BACKGROUND: Although aspiration and stent retriever thrombectomy perform similarly in proximal occlusions, no comparative series are available in distal occlusions. We aimed to compare the 3 mm Trevo Retriever against the 3MAX thromboaspiration catheter in distal arterial occlusions. METHODS: A single-center retrospective review of a prospectively maintained databank for patients treated with the 3 mm Trevo stent retriever or 3MAX thromboaspiration as the upfront approach for distal occlusions (middle cerebral artery mid/distal M2/M3, anterior cerebral artery A1/A2/A3 or posterior cerebral artery P1/P2) from January 2014 to July 2018 was performed. The primary outcome was the rate of distal occlusion first-pass reperfusion (modified Thrombolysis in Cerebral Infarction (mTICI) 2b-3). RESULTS: Of 1100 patients treated within the study period, 137 patients/144 different arteries were treated with the 3 mm Trevo (n=92) or 3MAX device (n=52). The groups had comparable demographics and baseline characteristics. There was a higher rate of first-pass mTICI 2b-3 reperfusion (62% vs 44%; p=0.03), a trend towards a higher rate of final mTICI 2b-3 reperfusion (84% vs 69%; p=0.05), and lower use of adjuvant therapy (15% vs 31%; p=0.03) with the 3 mm Trevo compared with the 3MAX. The median number of passes (p=0.46), frequency of arterial spasm (p=1.00), rates of parenchymal hematomas (p=0.22)/subarachnoid hemorrhage (p=0.37) in the territory of the approached vessel were similar across the two groups. The 90-day rate of good outcomes (45% vs 46% in the 3 mm Trevo and 3MAX groups, respectively; p=0.84) was comparable. Multivariable regression identified baseline NIH Stroke Scale (NIHSS) score (OR 0.9; 95% CI 0.8 to 0.97; p<0.01) and use of 3 mm Trevo (OR 2.2; 95% CI 1.1 to 4.6; p=0.02) independently associated with first-pass mTICI 2b-3 reperfusion. CONCLUSIONS: In the setting of distal arterial occlusions, the 3 mm Trevo may lead to higher rates of first-pass reperfusion than direct 3MAX thromboaspiration. Lower NIHSS was found to be associated with improved reperfusion rates as observed in more proximal lesions. Further studies are warranted.[Abstract] [Full Text] [Related] [New Search]