These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Simultaneous determination of 21 illegally added compounds in health foods by ultra high performance liquid chromatography-tandem mass spectrometry with solid phase extraction].
    Author: Xu D, Lai G, Chen Y, Luo C, Yi X, Deng X, Feng F, Zhang F.
    Journal: Se Pu; 2019 Jul 08; 37(7):778-785. PubMed ID: 31271019.
    Abstract:
    A rapid method for the simultaneous determination of 21 illegally added compounds in health foods was developed based on solid phase extraction (SPE) combined with ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After ultrasonic extraction with acetonitrile, the samples were purified on an HLB SPE column, separated on a Waters BEH C18 column (100 mm×2.1 mm, 1.7 μm) using 10 mmol/L ammonium acetate aqueous solution and methanol as the mobile phases. The compounds were detected by an electrospray ionization (ESI) source in positive ion mode with multi-reaction monitoring (MRM). The 21 illegal additives showed good linear relationships with correlation coefficients no less than 0.995. The limits of detection (LODs) were 3-160 μg/kg for different matrixes. The recoveries ranged from 61.8% to 109.3%, and the relative standard deviations ranged from 1.6% to 14.7%. The method can be used for the simultaneous determination of the illegally added drugs in the losing weight, lipid-lowering, anti-diabetic and anti-hypertension health foods.
    [Abstract] [Full Text] [Related] [New Search]