These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparative Stiffness of an Equine Distal Sesamoid Bone Fracture Model Stabilized with 3.5-mm versus 4.5-mm Cortical Bone Screws in Lag Fashion.
    Author: Mampe JR, Tatarniuk DM, Suarez-Fuentes DG, Kraus KH.
    Journal: Vet Comp Orthop Traumatol; 2019 Nov; 32(6):440-446. PubMed ID: 31279325.
    Abstract:
    OBJECTIVE:  The aim of this study was to to determine the comparative stiffness following repair of an axial sagittal fracture model in equine distal sesamoid bones using either a single 3.5-mm or 4.5-mm cortical bone screw placed in lag fashion. STUDY DESIGN:  The present study was an in vitro biomechanical study. RESULTS:  The mean (±standard deviation) stiffness value for the 4.5-mm screw-bone construct (522.49 N/mm ± 168.21) was significantly greater than the 3.5-mm screw-bone construct (408.46 N/mm ± 131.13) (p = 0.047). This represents a 28% difference in mean stiffness. CONCLUSIONS:  In vitro, the 4.5-mm screw-bone construct creates a stiffer repair of fractured distal sesamoid bones by a margin of 28%. The 4.5-mm cortical bone screw may better withstand forces imparted on the distal sesamoid bone sustained during anaesthetic recovery, normal weight bearing and athletic exercise, thereby minimizing the risk of implant failure.
    [Abstract] [Full Text] [Related] [New Search]