These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The UK National External Quality Assessment Scheme in Blood Group Serology. ABO and D grouping, antibody screening, direct antiglobulin test and antibody identification 1984-1985.
    Author: Holburn AM, Prior DM, Whitton CM.
    Journal: Clin Lab Haematol; 1988; 10(1):73-85. PubMed ID: 3130215.
    Abstract:
    In seven exercises of blood grouping the overall rates of major error were 0.19% and 0.25% in ABO and D grouping respectively. In ABO grouping this represents an increase in error rate over that observed in 1982-1983 but the increase was due to an unusually high error rate with one particular group A2B cell. An improvement in performance was observed in simple D grouping and was largely due to a lower incidence of false positive grouping of D-negative cells in the antiglobulin test. An improvement in performance observed in D grouping IgG-coated D-negative cells appeared to be due to a better understanding of the problem rather than to any change in serological practice. Error rates in antibody screening were somewhat lower than in 1982-1983 but this may or may not represent an improvement in performance as the test materials were not the same in the two periods. The direct antiglobulin test with IgG-coated cells was reliably performed with polyspecific and with anti-IgG reagents but an excess of false positive results was obtained with anti-C3d. Error rates in antibody identification varied from 0.6% for anti-D to 74% for anti-c + E.
    [Abstract] [Full Text] [Related] [New Search]