These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Hemofiltration clearance of flecainide in a patient with acute renal failure.
    Author: Borgeat A, Biollaz J, Freymond B, Bayer-Berger M, Chiolero R.
    Journal: Intensive Care Med; 1988; 14(3):236-7. PubMed ID: 3132493.
    Abstract:
    Flecainide, a new antiarrhythmic drug, has been shown not no be removed to a significant extent by hemodialysis or peritoneal dialysis, in spite of a high renal clearance. Its systemic and hemofiltrate clearances, measured in a patient under continuous hemofiltration, were 402 and 19.7 ml/min respectively. The clearance ratio of less than 5% makes the contribution of hemofiltration to the elimination of flecainide clinically negligible.
    [Abstract] [Full Text] [Related] [New Search]