  • Title: Long-Term Outcomes of the FORMA Transcatheter Tricuspid Valve Repair System for the Treatment of Severe Tricuspid Regurgitation: Insights From the First-in-Human Experience.
    Author: Asmarats L, Perlman G, Praz F, Hensey M, Chrissoheris MP, Philippon F, Ofek H, Ye J, Puri R, Pibarot P, Attinger A, Moss R, Bédard E, Moschovitis A, Reineke D, Lauck S, Blanke P, Leipsic J, Spargias K, Windecker S, Webb JG, Rodés-Cabau J.
    Journal: JACC Cardiovasc Interv; 2019 Aug 12; 12(15):1438-1447. PubMed ID: 31395213.
    Abstract:
    OBJECTIVES: To evaluate the long-term (≥2 years) outcomes following transcatheter tricuspid valve repair (TTVr) with the FORMA Transcatheter Tricuspid Valve Repair System (Edwards Lifesciences, Irvine, California). BACKGROUND: Scarce data exist on long-term outcomes following TTVr. METHODS: This multicenter experience included patients with severe tricuspid regurgitation (TR) who underwent TTVr with the FORMA system at 4 centers under a compassionate clinical use program. Data were collected at baseline, 30 days, and 1 year, and yearly thereafter. RESULTS: Nineteen patients (76 ± 9 years of age, 74% women, mean EuroSCORE II [European System for Cardiac Operative Risk Evaluation] 9.2 ± 5.6%) with functional TR were included. Procedural success was achieved in 17 (89%) patients and there were no cases of 30-day mortality. At a median follow-up of 32 (interquartile range: 24 to 36) months, 4 (24%) patients had died (3 from terminal heart failure, 1 from sepsis) and 3 (18%) patients required rehospitalization for heart failure. There was 1 device-related thrombosis and 1 pulmonary embolism, both in the setting of subtherapeutic oral anticoagulation. Less than severe TR was observed at echocardiography in 67% of patients at the 2- to 3-year follow-up. Among 15 successfully implanted patients with at least 24-month follow-up, significant improvements in New York Heart Association functional class (p < 0.001), 6-min walk test (+54 m; p = 0.016) and Kansas City Cardiomyopathy Questionnaire score (+16 points; p = 0.016) were observed, compared with baseline. CONCLUSIONS: TTVr using the FORMA system showed favorable long-term safety profile in high-surgical-risk patients, with sustained functional improvement and acceptable TR reduction up to 3 years.
    [Abstract] [Full Text] [Related] [New Search]