These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and inter-observer repeatability and comparison with point shear wave elastography. Author: Yoo J, Lee JM, Joo I, Yoon JH. Journal: Ultrasonography; 2020 Jan; 39(1):52-59. PubMed ID: 31623416. Abstract: PURPOSE: The purpose of this study was to prospectively investigate the intra- and interobserver repeatability of a new 2-dimensional (2D) shear wave elastography (SWE) technique (S-Shearwave Imaging) for assessing liver fibrosis in chronic liver disease patients, and to compare liver stiffness measurements (LSMs) made using 2D-SWE with those made using point SWE (pSWE). METHODS: This prospective study received institutional review board approval and informed consent was obtained from all patients. Fifty-three chronic liver disease patients were randomly allocated to group 1 (for intra-observer repeatability [n=33]) or group 2 (for inter-observer repeatability [n=20]). In group 1, two 2D-SWE sessions and one pSWE sessions were performed by one radiologist. In group 2, one 2D-SWE session and one pSWE session were performed by the aforementioned radiologist, and a second 2D-SWE session was performed by another radiologist. The intraclass correlation coefficient (ICC) was used to assess intra- and interobserver reliability. LSMs obtained using 2D-SWE and pSWE were compared and correlated using the paired t test and Pearson correlation coefficient, respectively. RESULTS: LSMs made using 2D-SWE demonstrated excellent intra- and inter-observer repeatability (ICC, 0.997 [95% confidence interval, 0.994 to 0.999]) and 0.995 [0.988 to 0.998], respectively). LSMs made using 2D-SWE were significantly different from those made using pSWE (2.1±0.6 m/sec vs. 1.9±0.6 m/sec, P<0.001), although a significant correlation existed between the 2D-SWE and pSWE LSMs (rho=0.836, P<0.001). CONCLUSION: S-Shearwave Imaging demonstrated excellent intra- and inter-observer repeatability, and a strong correlation with pSWE measurements of liver stiffness. However, because of the significant difference between LSMs obtained using 2D-SWE and pSWE, these methods should not be used interchangeably.[Abstract] [Full Text] [Related] [New Search]