These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Diagnostic Accuracy of Doppler Twinkling Artifact for Identifying Urinary Tract Calculi.
    Author: Adel H, Sattar A, Rahim A, Aftab A, Adil SO.
    Journal: Cureus; 2019 Sep 13; 11(9):e5647. PubMed ID: 31700749.
    Abstract:
    Introduction Flank pain is a frequent cause of emergency department visits and is often due to renal or ureteric colic. Ultrasound is often the initial imaging study used for the detection of urinary tract calculi. Twinkling artifact is a Doppler artifact usually seen on echogenic rough surfaces such as calculi. Its presence can improve the sensitivity and specificity of ultrasound in stone detection. The objective of the current study was to determine the diagnostic accuracy of the Doppler twinkling artifact for detecting urinary calculi using non-contrast computed tomography as the gold standard. Materials and methods In this cross-sectional study, both male and female patients of any age having flank pain, burning micturition with or without hematuria were included. Ultrasound was performed and the presence or absence of Doppler twinkling artifact on calculus was noted. Following ultrasound, patients underwent plain CT scan and findings of stones were documented. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of Doppler twinkling artifact was calculated considering CT findings as the gold standard. Results Out of the total 221 patients, 146 (66.1%) were males and 75 (33.9%) were females. The mean age of the patients was 45.98 ± 16.30 years. Urinary tract calculi on ultrasound were observed in 74 (33.50%) patients, while on CT urinary tract calculi were observed in 127 (57.50%) patients. Diagnostic accuracy of Doppler twinkling artifact was found to be 71.49% with sensitivity, specificity, positive predictive value, and negative predictive value of 54.33%, 94.68%, 93.24%, and 60.54%, respectively. Conclusion Doppler twinkling artifact has low sensitivity, high specificity, and suboptimal diagnostic accuracy for the diagnosis of urinary tract calculi. Integration of this artifact has a lower sensitivity as compared to non-contrast CT scan. Multicentric studies with larger sample size and focusing on interobserver and intraobserver variability are recommended to have a consensus regarding Doppler twinkling artifact in the evaluation of renal and ureteric calculi.
    [Abstract] [Full Text] [Related] [New Search]