These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Experience of Indian association of medical microbiology external quality assurance scheme centre, New Delhi: Challenges and quality assessment of clinical microbiology laboratories. Author: Wattal C, Oberoi JK, Goel N, Datta S, Raveendran R, Prasad KJ. Journal: Indian J Med Microbiol; 2019; 37(2):163-172. PubMed ID: 31745015. Abstract: INTRODUCTION: EQAS program at New Delhi under IAMM was started in January 2014 across North and North east regions of India with 217 participants, which grew up to 540 by 2018. MATERIALS AND METHODS: In 2014, 4 analytes per year were sent for 3 exercises, i.e. smear culture and serology. 2018 onwards PT analytes were increased from 4 to 12 and comparative performance of techniques analysed. RESULTS: Out of the 22 smears sent for gram staining, ZN staining, Kinyoun staining and Albert staining, completely correct results ranged between 29.55% - 79.9%, 94.3% - 99.2%, 35.5% & 93.8%, respectively. Correct results for culture isolate identification & susceptibility testing and serology exercises varied between 70 & 92.4% and 73.1 & 98.59%, respectively. In the year 2018, 470 responses were received for bacterial culture identification & antibiotic susceptibility testing out of which manual and automated systems were used by 54% & 46% and 52.5% & 47.5% participants, respectively. Techniques used in BBV assays for HBsAg, HCV & HIV found all methods like ELISA, ELFA, CLIA and Card Test performing similarly. The major challenges in running the EQA program included requirement of large amount of specimens for PT item preparation, stability in hot and humid conditions and timely delivery of PT challenges in remote parts of the country. CONCLUSION: A large number of the participating laboratories (77%) had an overall score of >80% for all exercises, demonstrating acceptable baseline performance of EQAS registered laboratories. However, continued EQAS participation could further improve the quality of results.[Abstract] [Full Text] [Related] [New Search]