These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Transfusion of Uncrossmatched Group O Erythrocyte-containing Products Does Not Interfere with Most ABO Typings. Author: Yazer MH, Spinella PC, Doyle L, Kaufman RM, Dunn R, Hess JR, Filho LA, Fontaine M, Gathof B, Jackson B, Murphy MF, Pasion J, Raval JS, Rosinski K, Seheult J, Shih AW, Sperry J, Staves J, Tuott EE, Ziman A, Triulzi DJ, Biomedical Excellence for Safer Transfusion Collaborative*. Journal: Anesthesiology; 2020 Mar; 132(3):525-534. PubMed ID: 31789634. Abstract: BACKGROUND: Group O erythrocytes and/or whole blood are used for urgent transfusions in patients of unknown blood type. This study investigated the impact of transfusing increasing numbers of uncrossmatched type O products on the recipient's first in-hospital ABO type. METHODS: This was a retrospective cohort study. Results of the first ABO type obtained in adult, non-type O recipients (i.e., types A, B, AB) after receiving at least one unit of uncrossmatched type O erythrocyte-containing product(s) for any bleeding etiology were analyzed along with the number of uncrossmatched type O erythrocyte-containing products administered in the prehospital and/or in hospital setting before the first type and screen sample was drawn. RESULTS: There were 10 institutions that contributed a total of 695 patient records. Among patients who received up to 10 uncrossmatched type O erythrocyte-containing products, the median A antigen agglutination strength in A and AB individuals on forward typing (i.e., testing the recipient's erythrocytes for A and/or B antigens) was the maximum (4+), whereas the median B antigen agglutination strength among B and AB recipients of up to 10 units was 3 to 4+. The median agglutination strength on the reverse type (i.e., testing the recipient's plasma for corresponding anti-A and -B antibodies) was very strong, between 3 and 4+, for recipients of up to 10 units of uncrossmatched erythrocyte-containing products. Overall, the ABO type of 665 of 695 (95.7%; 95% CI, 93.9 to 97.0%) of these patients could be accurately determined on the first type and screen sample obtained after transfusion of uncrossmatched type O erythrocyte-containing products. CONCLUSIONS: The transfusion of smaller quantities of uncrossmatched type O erythrocyte-containing products, in particular up to 10 units, does not usually interfere with determining the recipient's ABO type. The early collection of a type and screen sample is important.[Abstract] [Full Text] [Related] [New Search]