These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Application of different thresholds for instrumentation device testing in minimally invasive lumbosacral spine fixation. Author: Wu Y, Cohen D, Tellez MJ, DiGiacinto GV, Barquero AV, Ulkatan S. Journal: J Clin Neurosci; 2020 Feb; 72():224-228. PubMed ID: 31866354. Abstract: The main aim of this study was evaluating the reliability of stimulus-evoked electromyography (using different thresholds for stimulation of the instrumentation devices) for minimally invasive pedicle screw placement in the lumbosacral spine. A threshold of 5 mA was applied for the pedicle access needle. 7 mA was applied for the tapscrew and pedicle screw stimulation. The existence of threshold differences between vertebral levels was also assessed. All patients underwent postoperative computed tomography (CT) to determine the accuracy of pedicle screw placement. A total of 172 percutaneous pedicle screws were placed in 52 patients. 94.1% of screws were placed at L4, L5 and S1 vertebral levels. No statistically significant differences existed in thresholds of the pedicle access needles, tapscrews and pedicle screws between vertebral levels. In four instances, the pedicle access needle stimulation had a threshold of 5 mA (no breaches were associated). In the rest of occasions, the pedicle access needles had stimulation thresholds above 5 mA. In all instances, tapscrew and pedicle screw thresholds were above 7 mA; the tapscrews and pedicle screws had significantly greater thresholds than the pedicle access needles. No statistically significant differences existed in thresholds between tapscrews and pedicle screws. Postoperative CT imaging revealed one lateral pedicle violation. Both breach rate and false negative rate were 0.5%. No false positive cases were observed. No patients experienced postoperative pedicle screw-related neurologic deficits. A threshold of 5 mA for the pedicle access needle stimulation seems to be safe. Greater than 7 mA should be used for the tapscrew and pedicle screw stimulation.[Abstract] [Full Text] [Related] [New Search]