These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Bioengineered Acellular Dermal Matrix Spacer Grafts for Lower Eyelid Retraction Repair: A Report by the American Academy of Ophthalmology.
    Author: Tao JP, Aakalu VK, Wladis EJ, Sobel RK, Freitag SK, Foster JA, Yen MT.
    Journal: Ophthalmology; 2020 May; 127(5):689-695. PubMed ID: 31899031.
    Abstract:
    PURPOSE: To review the literature on the efficacy and safety of bioengineered acellular dermal matrix (BADM) grafts for lower eyelid retraction repair. METHODS: A literature search was conducted in the PubMed database initially in January 2018 and updated in July 2019 to identify all studies in the English language literature on the use of BADM grafts in eyelid reconstruction. The searches yielded 193 citations, and 15 of the 34 articles selected for full review met all inclusion criteria for this assessment. A panel methodologist then assigned a level of evidence rating for each study. Two of the 15 studies included were rated level II and 13 were rated level III. RESULTS: The definition of success varied, but lower eyelid position improvement using lower lid margin-to-pupillary reflex distance was the most common outcome measure. Other end points were the amount of lagophthalmos, cosmesis, exposure, reoperation, or complications, as well as prosthesis retention in anophthalmic socket cases. The surgeon-reported success rate of these outcomes ranged from 75% to 100%. Minor complications included cyst formation, infection, chemosis, pyogenic granuloma, and corneal abrasion. No serious complications such as blindness, anaphylactic reaction, or terminal disease transmission occurred. Of the 526 implants included for assessment in these disparate studies, 27 cases (5%) required reoperation. CONCLUSIONS: No level I evidence was available, and the existing level II and level III studies have variable primary end points, study design limitations, and only short-term follow-up data. The current literature suggests that BADM grafts represent an implantation option for lower eyelid retraction repair. Short-term results are favorable, and the materials used may fill an important gap in care for patients for whom no acceptable alternatives exist, but long-term safety and efficacy remain unknown.
    [Abstract] [Full Text] [Related] [New Search]