These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Optical Coherence Tomography Structural Abnormality Detection in Glaucoma Using Topographically Correspondent Rim and Retinal Nerve Fiber Layer Criteria. Author: Yang H, Luo H, Hardin C, Wang Y, Jeoung JW, Albert C, Vianna JR, Sharpe GP, Reynaud J, Demirel S, Mansberger SL, Fortune B, Nicolela M, Gardiner SK, Chauhan BC, Burgoyne CF. Journal: Am J Ophthalmol; 2020 May; 213():203-216. PubMed ID: 31899204. Abstract: PURPOSE: This study evaluated the ability of topographically correspondent (TC) minimum rim width (MRW) and peripapillary retinal nerve fiber layer thickness (pRNFLT) criteria to detect optical coherence tomography (OCT) structural abnormality in glaucoma (GL) and glaucoma suspect (GLS) eyes. DESIGN: Retrospective cross-sectional study. METHODS: A total of 196 GL eyes, 150 GLS eyes, and 303 heathy eyes underwent pRNFL and 24 radial optic nerve head OCT imaging and manual correction of the internal limiting membrane, Bruch's membrane opening (BMO), and outer pRNFL segmentations. MRW and pRNFLT were quantified in 6 Garway-Heath or 12 30-degree (clock-hour) sectors. OCT abnormality for each parameter was defined to be less than the 5th percentile of the healthy eye distribution. OCT abnormality for individual eyes was defined using global, sectoral, and combined parameter criteria that achieved ≥95% specificity in the healthy eyes. TC combination criteria required the sectoral location of MRW and pRNFLT abnormality to be topographically aligned and included comMR (a previously reported TC combination consisting of MRW and pRNFLT parameter: [MRW + pRNFLT × (average MRW healthy eyes/average pRNFLT healthy eyes) MRW]. RESULTS: TC sectoral criteria (1 Garway-Heath MRW + corresponding Garway-Heath RNFLT), (one 30-degree MRW + any 1 corresponding or adjacent 30-degree pRNFLT), 30-degree and Garway-Heath comMR-TI and global comMR were the best performing criteria, demonstrating (96%-99% specificity), 86%-91% sensitivity for GL, 80%-84% sensitivity for early GL (MD ≥ -4.0 dB) and 93%-96% sensitivity for moderate-to-advanced GL (MD < -4.0 dB). CONCLUSIONS: Clinically intuitive TC MRW and pRNFLT combination criteria identified the sectoral location of OCT abnormality in GL eyes with high diagnostic precision.[Abstract] [Full Text] [Related] [New Search]