These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Drug-coated balloon angioplasty: predicting outcomes based on different patterns of drug-eluting stent restenosis.
    Author: Wang X, Lu W, Wang X, Pan L, Fu W, Liu Q, Han Z, Sun G, Qin X, Li R, Zheng X, Shan Y, Qiu C.
    Journal: Int J Cardiovasc Imaging; 2020 Feb; 36(2):171-178. PubMed ID: 31919705.
    Abstract:
    Although drug-coated balloon (DCB) angioplasty is an effective therapy for drug-eluting stent- in stent restenosis (DES-ISR) after coronary stenting, recurrent ISR after DCB angioplasty still occurs. Different patterns of DES-ISR responding to DCB are largely unknown. This study sought to assess outcomes of different patterns of DES-ISR treated with DCB. From December 2014 to December 2016, a total of 160 DES-ISR lesions treated with DCB were retrospectively evaluated. Restenosis patterns were classified into two groups according to Mehran classification: focal, defined as < 10 mm, 58 lesions (36.3%); non-focal, which were diffuse, proliferative, or obstructive, 102 lesions (63.7%). The primary endpoint was binary restenosis rate at 9-month angiographic follow-up. Secondary endpoint was major adverse cardiac events (MACE) at 24-month follow-up. Baseline characteristics were comparable between the two groups. Angiographic follow-up rate was 93.7% (93.1% in the focal group and 94.1% in the non-focal group). The focal group had a lower recurrent restenosis rate compared to the non-focal group (3.7% vs. 33.3%, respectively; P = 0.003) at an average angiographic follow-up of 10 (10.4 ± 6.2) months. There was no difference in MACE between the two groups (6.9% vs. 11.8%, respectively; P = 0.70) at (22.7 ± 9.1) months clinical follow-up. On multivariate logistic regression analysis, focal pattern (OR 13.033; 95% CI 2.441-69.573, P = 0.003) and post-procedure DS% (OR 1.142; 95% CI 1.070-1.218, P = 0.000) were predictive factors of binary restenosis after DCB angioplasty. On multivariate analysis, focal pattern of ISR was a predictive factor of MACE (OR 0.260; 95% CI 0.071-0.959, P = 0.043), and diabetes mellitus (DM) was an independent predictor of MACE after DCB angioplasty (OR 5.045; 95% CI 1.179-21.590, P = 0.029). The present study suggests that DCB provides much better clinical, angiographic outcomes in patients with focal DES-ISR than non-focal DES-ISR.
    [Abstract] [Full Text] [Related] [New Search]