These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Intramedullary screw fixation for metacarpal shaft fractures: a biomechanical human cadaver study.
    Author: Labèr R, Jann D, Behm P, Ferguson SJ, Frueh FS, Calcagni M.
    Journal: J Hand Surg Eur Vol; 2020 Jul; 45(6):595-600. PubMed ID: 31948331.
    Abstract:
    Intramedullary cannulated compression screws have been introduced for the fixation of unstable metacarpal fractures. In the present study, this technique was compared with dorsal compression plating to evaluate its biomechanical performance in stabilizing metacarpal shaft fractures. In a first set of experiments, the biomechanical characteristics of the screws were analysed in an artificial bone model. In subsequent experiments, midshaft osteotomies were performed in human cadaver metacarpals, followed by plating or intramedullary screw osteosynthesis. The metacarpals were tested to failure in cantilever bending, following a stepwise increasing cyclic loading protocol. We found a significantly lower load at failure and a significantly lower number of cycles to failure in the intramedullary screw group, but both methods offered sufficient stability under these loads. With reference to published loads on the metacarpals during use of the hand, we conclude that intramedullary osteosynthesis yields sufficient strength and stiffness for early active motion. A difference in its fixation stability is noted compared with plate fixation, which may not be clinically relevant.
    [Abstract] [Full Text] [Related] [New Search]