These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Aortic valve repair with a newly approved geometric annuloplasty ring in patients undergoing proximal aortic repair: early results from a single-centre experience.
    Author: Jawitz OK, Raman V, Anand J, Bishawi M, Voigt SL, Doberne J, Vekstein AM, Weissler EH, Turek JW, Hughes GC.
    Journal: Eur J Cardiothorac Surg; 2020 Jun 01; 57(6):1137-1144. PubMed ID: 32011669.
    Abstract:
    OBJECTIVES: Aortic insufficiency (AI) is common in patients with proximal aortic disease, but limited options exist to facilitate aortic valve repair (AVr) in this population. This study reports 'real-world' early results of AVr using newly FDA-approved trileaflet and bicuspid geometric annuloplasty rings for patients with AI undergoing proximal aortic repair (PAR) in a single referral centre. METHODS: All patients undergoing AVr with a rigid internal geometric annuloplasty ring (n = 47) in conjunction with PAR (ascending +/- root +/- arch) were included. Thirty-six patients underwent AVr with a trileaflet ring, and 11 patients underwent AVr with a bicuspid ring. The rings were implanted in the subannular position, and concomitant leaflet repair was performed if required for cusp prolapse identified after ring placement. RESULTS: The median age was 58 years [interquartile range (IQR) 46-70]. PAR included supracoronary ascending replacement in 26 (55%) patients and remodelling valve-sparing root replacement with selective sinus replacement in 20 (42%) patients. Arch replacement was performed in 38 (81%) patients, including hemi-arch in 34 patients and total arch in 4 patients. There was no 30-day/in-hospital mortality. Preoperative AI was 3-4+ in 37 (79%) patients. Forty-one (87%) patients had zero-trace AI on post-repair transoesophageal echocardiography, and 6 patients had 1+ AI. The median early post-repair mean gradient was 13 mmHg (IQR 5-20). Follow-up imaging was available in 32 (68%) patients at a median of 11 months (IQR 10-13) postsurgery. AI was ≤1+ in 97% of patients with 2+ AI in 1 patient. All patients were alive and free from aortic valve reintervention at last follow-up. CONCLUSIONS: Early results with geometric rigid internal ring annuloplasty for AVr in patients undergoing PAR appear promising and allow a standardized approach to repair with annular diameter reduction and cusp plication when needed. Longer-term follow-up will be required to ensure the durability of the procedure.
    [Abstract] [Full Text] [Related] [New Search]