These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effect of a Condom Cover on Vaginal Photoplethysmographic Responses. Author: Sawatsky ML, Lalumière ML. Journal: J Sex Med; 2020 Apr; 17(4):702-715. PubMed ID: 32035833. Abstract: INTRODUCTION: The vaginal photoplethysmograph (VPP) is a reusable intravaginal device often employed in sexual psychophysiology studies to assess changes in vaginal blood flow, an indicator of sexual arousal. AIM: To test whether placing a disposable cover on the VPP probe impacts the acquired data. A condom cover would reduce risk of disease transmission and likely increase participant comfort but may negatively impact the VPP signal. METHOD: The genital responses of 25 cisgender women (mean age = 21.3 years, standard deviation = 2.6) were assessed with VPP in a within-subjects design with 2 conditions-with and without a polyisoprene condom cover. Sexual responses were elicited by audiovisual film clips that varied in erotic intensity: nonsexual (nonsexual male-female interaction), low-intensity sexual (nude exercise), and high-intensity sexual (male-female intercourse). Women continuously rated their sexual arousal during stimulus presentations. MAIN OUTCOME MEASURE: Change in vaginal pulse amplitude and also self-reported sexual arousal. RESULTS: The magnitude of sexual response to each stimulus category and the overall pattern of results were found to be highly similar in the cover-off and cover-on conditions. The high-intensity sexual stimulus category elicited a greater sexual response than all other categories. The low-intensity sexual category elicited a (small) genital response in only the cover-on condition, although we suspect this is a spurious finding. There was no difference in the average number of edited movement artifacts across conditions. CLINICAL IMPLICATIONS: Potential benefits of encasing the VPP probe with a protective cover include enhanced participant safety and comfort, especially if assessing genital responses of high-risk or immunocompromised samples. The use of a cover complies with current guidelines for reprocessing semi-critical medical devices (eg, vaginal ultrasound probes) in many regions. STRENGTHS & LIMITATIONS: Although the idea of a VPP probe cover had been discussed among sexual psychophysiology researchers, this is the first study to empirically test whether a cover could jeopardize VPP data. Potential limitations include the use of a 10-Hz VPP sampling rate and a cover that was not tailored to the size of the VPP probe. CONCLUSION: Placing a protective cover on the VPP probe did not appear to meaningfully impact sexual arousal or the VPP data. Based on these results and the potential advantages of a protective cover, researchers may wish to integrate the use a condom cover in their experiment protocols and clinical applications. Sawatsky ML, Lalumière ML. Effect of a Condom Cover on Vaginal Photoplethysmographic Responses. J Sex Med 2020; 17:702-715.[Abstract] [Full Text] [Related] [New Search]