These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Stretched-exponential and mono-exponential diffusion-weighted imaging for assessing the aggressiveness of prostate cancer: A histogram analysis].
    Author: Yu YN, Zhang SJ.
    Journal: Zhonghua Nan Ke Xue; 2019 Dec; 25(12):1106-1112. PubMed ID: 32251563.
    Abstract:
    OBJECTIVE: To assess the value of stretched-exponential and mono-exponential diffusion-weighted imaging (DWI) in predicting the aggressiveness of PCa. METHODS: This retrospective study included 36 cases of PCa with 48 lesions in the peripheral zone diagnosed by DWI with b-values of 0, 500, 1000, and 2000 s/mm2. We reconstructed the apparent diffusion coefficient (ADC), distributed diffusion coefficient (DDC) and α maps on the post-processing workstation, performed a histogram analysis on the largest slice of PCa on T2WI and Spearman's rank-order analysis on the correlation of the histogram variables with Gleason grade grouping (GG). Then, we assessed the values of the histogram variables in differentiating low-grade from high-grade PCa using the receiver operating characteristic (ROC) curve. RESULTS: The percentile and mean ADCs and DDCs were correlated with GG (ρ: 0.392-0.641) but not the α value, skewnesses and kurtosises (ρ: 0.055-0.266). High-grade PCa exhibited significantly lower 10th-, 25th-, 50th- and 75th-percentile and mean ADCs (490 ± 141, 591 ± 137, 695 ± 137, 781 ± 139 and 888 ± 135 mm2/s) and DDCs (420 ± 146, 534 ± 167, 666 ± 182, 787 ± 190 and 912 ± 175 mm2/s) than low-grade PCa (ADCs: 636 ± 74, 727 ± 86, 825 ± 85, 907 ± 85 and 975 ± 117 mm2/s; DDCs: 542 ± 80, 666 ± 93, 806 ± 108, 910 ± 110 and 1023 ± 105 mm2/s), but there were no statistically significant differences between low- and high-grade PCa in the α value (0.67 ± 0.042 vs 0.64 ± 0.036), kurtosises (ADC 0.105 vs 0.078; DDC -0.027 vs -0.401) or skewnesses (ADC -0.042 vs 0.067; DDC -0.058 vs 0.162). Both 10th-percentile ADCs and DDCs showed a higher efficiency than the mean ones in differentiating high- from low-grade PCa, though with no statistically significant difference (P > 0.05). CONCLUSIONS: Histogram variables DDCs and ADCs, rather than the α value, can be used to predict the aggressiveness of PCa, even more efficiently at the 10th percentile than on the mean.
    [Abstract] [Full Text] [Related] [New Search]