These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A pilot study of the shapes of ablation lesions in the canine prostate by laser, radiofrequency and microwave and their clinical significance. Author: Liu R, Duan S, Cao H, Cao G, Chang Z, Zhang Y, Li Y, Wu Y, Liu L, Zhang L. Journal: PLoS One; 2020; 15(4):e0223229. PubMed ID: 32271751. Abstract: To explore the shape characteristics of ablation lesions created via laser ablation (LA), radiofrequency ablation (RFA) and microwave ablation (MWA) in canine prostates and the clinical significance of these characteristics, six adult male beagles were randomly assigned to the LA, RFA, and MWA groups. These ablations were performed with common parameters applied in clinical practice (LA, 3 W/1200 J; RFA and MWA, 30 W/120 s). One ablation lesion was created in each lobe of the prostate via the ablation technique, resulting in a total of twelve ablation lesions. Transrectal ultrasound (TRUS) was used as guidance during puncture and to monitor changes in the ablation lesions. Finally, the ablation efficacy was assessed using transrectal contrast-enhanced ultrasonography (CEUS), and the transverse diameter (TRD), anteroposterior diameter (APD) and longitudinal diameter (LD) of each ablation lesion were measured. The volume (V) and the ratio (R) value were calculated. R reflects the shape characteristic of the ablation lesion (the R value close to 1.0 indicates a more spherical shape). The R values of the ablation lesions were 0.89 ± 0.02, 0.72 ± 0.01, and 0.65 ± 0.03 for RFA, MWA and LA, respectively, and they were significantly different (P = 0.027). The volumes of the ablation lesions were 2.17 ± 0.10 ml, 1.51 ± 0.20 ml, and 0.79 ± 0.07 ml for MWA, LA and RFA, respectively, and they were also significantly different (P = 0.001). The three abovementioned thermal ablation techniques with common parameters in clinical practice can be used for ablation in the prostate. The shapes and volumes of the ablation lesions of the three techniques were varied: The RFA-created lesions had the lowest volumes and were more spherical in shape, demonstrating that RFA could be used for the treatment of relatively small lesions or tumours adjacent to vital organs. The MWA lesions had the largest size with a spherical shape, which could be advantageous for the ablation of tumours with relatively large sizes. The sizes of the ablation lesions created via LA were between those of RFA and MWA but presented more oval in shape, suggesting that this method is highly appropriate for the ablation of benign prostatic hyperplasia (BPH).[Abstract] [Full Text] [Related] [New Search]