These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evaluation of serum separator tubes as a mail transport device in primary health care.
    Author: Sandberg S, Christensen NG, Horgen E, Jacobsen H, Johansen K.
    Journal: Scand J Prim Health Care; 1988 Nov; 6(4):251-4. PubMed ID: 3231943.
    Abstract:
    Serum separator tubes were evaluated as a serum separator system and a mail transport device. Using conventional tubes as controls, 26 serum constituents were examined. The samples were mailed from three different general practitioners to a central laboratory. Thirteen constituents had concentrations that were significantly different from the concentration in the conventional tubes. When medically important coefficients of variations were taken into account, however, the changes of only two constituents (potassium and cobalamin) were regarded as important.
    [Abstract] [Full Text] [Related] [New Search]