These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Assessment of biliary anatomy in potential living liver donors: Added value of gadoxetic acid-enhanced T1 MR Cholangiography (MRC) including utilization of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique in comparison to T2W-MRC. Author: Guimaraes L, Babaei Jandaghi A, Menezes R, Grant D, Cattral M, Jhaveri KS. Journal: Magn Reson Imaging; 2020 Jul; 70():64-72. PubMed ID: 32320722. Abstract: OBJECTIVES: To assess the added value of gadoxetic-acid-enhanced T1-weighted magnetic resonance Cholangiography (T1W-MRC) including controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-Volumetric Interpolated Breathhold (VIBE) technique compared to T2-weighted MR Cholangiography (T2W-MRC) in depicting biliary anatomy in potential living liver donors. METHODS: Eighty-five potential donors including 34 men with a mean age of 35.6 years (range, 18-55 years) and 51 women with a mean age of 36.7 years (range, 23-57 years), were enrolled in this ethics-approved retrospective study. Image quality for depiction of bile ducts was evaluated by two readers in consensus in 3 separate reading sessions: 1) T2W-MRC alone, 2) T1W-MRC alone (including CAIPI-VIBE and generalized autocalibrating partially parallel acquisitions (GRAPPA)-VIBE techniques, and 3) combined T1W/T2W-MRC. Accuracy of T2W-MRC, T1W-MRC, and combined T1W/T2W-MRC for the identification/classification of the biliary variants was calculated using intraoperative cholangiogram (IOC) as the reference standard. Image quality and reader diagnostic confidence provided by CAIPI-VIBE technique was compared with GRAPPA-VIBE technique. Datasets were compared using the Wilcoxon signed-rank test. RESULTS: Image quality for depiction of the bile ducts was significantly superior in the combined T1W/T2W-MRC group, when compared to each of T2W-MRC and T1W-MRC groups independently (P value = 0.001-0.034). The combination of CAIPI-VIBE and GRAPPA-VIBE was superior compared to each of the sequences individually. The accuracy of T2W-MRC and T1W-MRC was 93% and 91%, respectively. T1W-MRC depicted four biliary variants better than T2W-MRC. Two variants not well seen in T2W-MRC were clearly shown on T1W-MRC. CONCLUSION: Gadoxetic-acid-enhanced T1W-MRC and conventional T2W-MRC techniques are complementary for depiction of biliary variants in potential liver donors and the combination of the two improves the results. The combination of CAIPI-VIBE and GRAPPA-VIBE techniques appear to be complementary for optimal diagnostic yield of T1W-MRC.[Abstract] [Full Text] [Related] [New Search]