  • Title: Augmented teicoplanin clearance through probable adsorption onto a polymethyl methacrylate (PMMA) hemofilter during continuous venovenous hemodiafiltration.
    Author: Oda K, Jono H, Sagishima K, Saito H.
    Journal: J Infect Chemother; 2020 Sep; 26(9):992-994. PubMed ID: 32334950.
    Abstract:
    Teicoplanin, a glycopeptide antibiotic against Gram-positive bacteria, is used during continuous venovenous hemodiafiltration (CVVHDF), though adsorption onto a hemofilter has been observed in an in-vitro study. We report a case of extensive augmentation of teicoplanin clearance by a polymethyl methacrylate (PMMA) hemofilter. A 74-year-old man (body weight 53 kg) was performed CVVHDF with the PMMA hemofilter. The effluent flow rate maintained at 600-650 mL/h. The measured teicoplanin clearance was 31.0 mL/min, and the clearance was reduced to 11.1 mL/min over the next 6.5 hours. In conclusion, we should closely monitor teicoplanin dosing during CVVHDF using a PMMA membrane hemofilter.