These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Programmed Death-Ligand 1 Immunohistochemistry Assay Comparison Studies in NSCLC: Characterization of the 73-10 Assay. Author: Grote HJ, Feng Z, Schlichting M, Helwig C, Ruisi M, Jin H, Scheuenpflug J, Gann CN, Su Z, Reck M, Vokes EE, Kerr KM. Journal: J Thorac Oncol; 2020 Aug; 15(8):1306-1316. PubMed ID: 32353599. Abstract: INTRODUCTION: Several programmed death-ligand 1 (PD-L1) immunohistochemistry (IHC) assays have been developed independently within clinical programs for therapeutic anti-programmed cell death protein 1 (anti-PD-1) or PD-L1 antibodies, necessitating assessment of assay comparability. We characterized the Dako PD-L1 IHC 73-10 assay used in clinical trials of avelumab (anti-PD-L1) or bintrafusp alfa (M7824; bifunctional immunotherapy) and compared it with the Dako PD-L1 IHC 22C3 pharmDx assay, an approved companion diagnostic for pembrolizumab monotherapy in patients with advanced NSCLC. METHODS: Formalin-fixed, paraffin-embedded NSCLC tumor samples from a commercial source and from the JAVELIN Solid Tumor phase 1 trial of avelumab (NCT01772004) were stained using the 73-10 and 22C3 IHC assays with a standard protocol. RESULTS: Both assays displayed expected PD-L1 staining patterns. In 148 commercial NSCLC samples, the 73-10 assay stained greater than or equal to 1%, greater than or equal to 50%, and greater than or equal to 80% of tumor cells as PD-L1+ in 64.2%, 36.5%, and 23.6% of the samples, respectively, whereas the 22C3 assay stained 20.3% of the samples as greater than or equal to 50% PD-L1+. In 83 NSCLC clinical trial samples, the 73-10 assay stained 79.5% and 31.3% of the samples as greater than or equal to 1% and greater than or equal to 80% PD-L1+, respectively, whereas the 22C3 assay stained 59.0% and 21.7% as greater than or equal to 1% and greater than or equal to 50% PD-L1+, respectively. Efficacy of avelumab was similar in the subgroups classified with the 73-10 and 22C3 assays using greater than or equal to 80% and greater than or equal to 50% PD-L1+ cutoffs, with objective response rates of 26.9% and 33.3%, respectively. CONCLUSIONS: The 73-10 assay demonstrated high sensitivity for PD-L1 staining, and staining was comparable between the greater than or equal to 80% cutoff of the 73-10 assay and greater than or equal to 50% cutoff of the 22C3 assay.[Abstract] [Full Text] [Related] [New Search]