These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparison of Low-Profiled Visualized Intraluminal Support Stent-Assisted Coiling and Coiling Only for Acutely Ruptured Intracranial Aneurysms: Safety and Efficacy Based on a Propensity Score-Matched Cohort Study.
    Author: Xue G, Zuo Q, Tang H, Zhang X, Duan G, Feng Z, Li Q, Yang P, Fang Y, Zhao K, Dai D, Xu Y, Hong B, Huang Q, Zhao R, Liu J.
    Journal: Neurosurgery; 2020 Sep 01; 87(3):584-591. PubMed ID: 32415845.
    Abstract:
    BACKGROUND: Low-profiled visualized intraluminal support (LVIS) is suggested as a promising stent for complex intracranial aneurysms. However, the safety and efficacy of LVIS-assisted coiling of acutely ruptured wide-necked intracranial aneurysms have not been well reported. OBJECTIVE: To evaluate the safety and efficacy of LVIS-assisted coiling of acutely ruptured wide-necked intracranial aneurysms compared with contemporary coiling-only strategy via propensity score matching in a high-volume center. METHODS: A retrospective review of patients with acutely ruptured intracranial aneurysms who underwent LVIS stent placement or coiling only from November 2013 to October 2017 was performed. Perioperative procedure-related complications and clinical and angiographic follow-up outcomes were compared. RESULTS: All baseline characteristics were equivalent between the 2 groups except for neck size. The immediate angiographic results, procedure-related complications, procedure-related mortality, and clinical outcomes between the 2 groups demonstrated no significant differences (P = .087, P = .207, P = .685, and P = .865, respectively). The angiographic follow-up outcomes of the LVIS-assisted coiling group showed a significantly higher complete occlusion rate and lower recurrence rate compared with the coiling-only group (92.3% vs 59.9%, 4.8% vs 26.1%, P < .001). Multivariable analysis showed no significant predictors for the overall perioperative procedure-related complications, hemorrhagic complications, and ischemic complications. CONCLUSION: The LVIS stent is a safe and effective device for stent-assisted coiling of acutely ruptured wide-necked intracranial aneurysms, with comparable procedure-related complication rates, higher complete occlusion rates, and lower recurrence rates at follow-up compared with coiling only.
    [Abstract] [Full Text] [Related] [New Search]