These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Posterolateral plating is a safe alternative for the treatment of distal tibial fractures.
    Author: Schloss MG, Ghulam QM, Hannan ZD, O'Hara NN, Napora JK, McAlister IP, Atchison J, Mulliken A, Zaidi SM, Nascone JW, O'Toole RV, Manson TT.
    Journal: Injury; 2020 Jul; 51(7):1662-1668. PubMed ID: 32434717.
    Abstract:
    INTRODUCTION: We assessed the outcome and safety of posterior plating of distal tibial fractures. METHODS: We conducted a retrospective case series at a Level I trauma center. Seventy-four consecutive patients with distal tibial fractures treated with anatomically contoured 3.5-mm T-shaped locking compression plate using a posterolateral approach from January 2008 through April 2018 were included in the study. The mean patient age was 48 years (range, 18-87 years). Fifty-nine percent of the patients were male patients, 47% of the fractures were open fractures; and 27% of the patients had multiple traumatic injuries. Eleven fractures were AO/OTA type 42, 22 were type 43A, and 41 were type 43C. Sixty-two (84%) patients were treated with initial spanning external fixation (median time, 23 days) and staged open reduction and internal fixation. The main outcome measure was unplanned reoperation to address implant failure, nonunion, deep surgical site infection, or symptomatic implant. RESULTS: Overall risk of unplanned reoperation was 15% (11 of 74 patients, 95% confidence interval, 9%-25%). Four (5%) reoperations were for nonunion, three (4%) were for surgical site infection, two (3%) were for infected nonunion, and two (3%) were for implant prominence. Loss of alignment >10 degrees occurred in one patient who underwent unplanned reoperation for nonunion. No plate breakage occurred. Median time to reoperation was 221 days (range, 22-436 days). Only one other complication was noted: wound dehiscence associated with the posterolateral approach, which was treated with irrigation and débridement and a 6-week regimen of oral antibiotics. CONCLUSIONS: Use of a posterolateral approach with a pre-contoured locking compression T-plate for the treatment of distal tibial fractures led to reasonable outcomes with an acceptable risk of unplanned reoperation, even with a high proportion of open fractures commonly staged with external fixation.
    [Abstract] [Full Text] [Related] [New Search]