Search MEDLINE/PubMed
Title: Effects of cerebellar retraction on brainstem auditory evoked potentials in an experimental animal model of cerebellopontine angle tumor. Author: Lumenta C, Reschofsky K, Bock W. Journal: Surg Neurol; 1988 Feb; 29(2):108-14. PubMed ID: 3257305. Abstract: The effects of cerebellar retraction on brainstem auditory evoked potentials (BAEPs) were studied in 15 New Zealand rabbits. In the first series, a Fogarty catheter was placed in the cerebellopontine angle of 5 rabbits. When a balloon volume of 0.2 mL was produced, only the latencies of waves III-V of the ipsilateral side increased. With a volume of 0.4 mL the ipsilateral BAEPs were irreversibly lost and the contralateral one reversibly changed. A volume of 0.6 mL caused loss of the BAEP on both sides and death of the animal. In another series, the cerebellum of 10 rabbits was retracted by a self-retaining retractor laterally to medially, so an approach to the cerebellopontine angle was simulated. With a retraction of up to 36 power units (p) the ipsilateral BAEPs were reversibly changed. A retraction of 54 p caused irreversible loss of wave V on both sides. With 84 p ipsilateral and contralateral waves III-V were immediately lost. The animals died within 7 minutes. Our experimental investigation shows that not only a defined volume in the cerebellopontine angle can cause irreversible impairment of brainstem function, but also uncontrolled retraction of the cerebellum.[Abstract] [Full Text] [Related] [New Search]