These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Cardiac Resynchronization Therapy and Risk of Recurrent Hospitalizations in Patients Without Left Bundle Branch Block: The Long-Term Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy. Author: Vidula H, Lee E, McNitt S, Polonsky B, Aktas M, Rosero S, Younis A, Solomon SD, Zareba W, Kutyifa V, Goldenberg I. Journal: Circ Heart Fail; 2020 Jul; 13(7):e006925. PubMed ID: 32605387. Abstract: BACKGROUND: Mild heart failure (HF) patients without left bundle branch block (LBBB) did not derive a significant reduction in risk of a HF event/death in the MADIT-CRT trial (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy). However, the efficacy of CRT with a defibrillator (CRT-D) may be modified after the development of the first hospitalization for HF (HHF). We aimed to study the effect of CRT-D on long-term risk of recurrent HHF in patients without LBBB in MADIT-CRT. METHODS: Data on recurring HHF were collected for 1818 subjects. The CRT-D versus implantable cardioverter-defibrillator-only risk for first and subsequent HHF was assessed by QRS morphology in on-treatment analysis using Cox proportional hazards regression modeling. RESULTS: During long-term follow-up, 412 patients had ≥1 HHF and 333 had ≥2 HHF. Multivariate analysis revealed that in LBBB patients, CRT-D, compared with implantable cardioverter-defibrillator, was associated with a significant reduction in risk of first and subsequent HHF (first: hazard ratio, 0.41 [95% CI, 0.31-0.54], P<0.001; subsequent: hazard ratio, 0.45 [95% CI, 0.29-0.70], P<0.001). Among patients without LBBB, the benefit of CRT-D was nonsignificant for the first HHF (hazard ratio, 0.96; P=0.808). However, after occurrence of a first HHF, CRT-D therapy was associated with a pronounced 44% reduction in risk of subsequent HHF (hazard ratio, 0.56 [95% CI, 0.32-0.97], P=0.039). Patients without LBBB with ≥1 HHF during the first year of follow-up demonstrated increasing dyssynchrony at 1 year compared with those who had no HHF (P=0.016). CONCLUSIONS: In MADIT-CRT, we show a beneficial effect of CRT-D in patients without LBBB subsequent to development of a first HHF, possibly due to increased dyssynchrony associated with HF progression. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00180271, NCT01294449, and NCT02060110.[Abstract] [Full Text] [Related] [New Search]