These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Performance and Safety of Transfemoral TAVI With SAPIEN XT in Australian Patients With Severe Aortic Stenosis at Intermediate Surgical Risk: SOLACE-AU Trial. Author: Yong G, Walton T, Ng M, Gurvitch R, Worthley S, Whitbourn R, Jepson N, Bhindi R, Shang K, Sinhal A. Journal: Heart Lung Circ; 2020 Dec; 29(12):1839-1846. PubMed ID: 32712017. Abstract: BACKGROUND: To determine the safety and performance of the SAPIEN XT transcatheter heart valve (THV) in Australian patients with severe aortic stenosis (AS) and intermediate surgical risk. METHODS: Eligible patients in this multi-centre, prospective, consecutively enrolled, non-randomised, clinical trial, received transcatheter aortic valve replacement via femoral artery access. Follow-up visits were at discharge, 30 days, and 6, 12, and 24 months. The primary endpoint was Valve Academic Research Consortium-2 composite safety at 30 days: all-cause mortality, all stroke, life-threatening bleeding, acute kidney injury-Stage 3, coronary artery obstruction requiring intervention, major vascular complication, and valve-related dysfunction requiring repeat procedure. Other endpoints were device success (successful vascular access, delivery, and deployment; correct position; intended performance mean aortic valve gradient <20 mmHg, mild or less paravalvular aortic regurgitation [PAR]; and only one valve implanted) and New York Heart Association functional class (NYHA). Kaplan-Meier (KM) estimates were calculated for the primary endpoint. RESULTS: At baseline, mean patient (N=199) age was 85.5 years, mean Society of Thoracic Surgeon score was 5.9, and 78.4% were in NYHA class III/IV. The primary composite endpoint KM estimate was 12.1%. Device success was 88.8%. SAPIEN XT was implanted in the proper location in 98.5% (n=2: valve-in-valve procedures, n=1: no implant due to left main coronary artery occlusion). No device malfunctions were reported. The post procedure PAR was mild or less in 93.8% of patients. Mean aortic gradient decreased from baseline (50.0 mmHg) to 2 years (10.3 mmHg). Most patients (90.9%) were in NYHA class I/II at 30 days. New permanent pacemaker rate was 8.1%. Stroke at 30 days was 3.5% (1.5% disabling). CONCLUSION: SAPIEN XT was safe and improved heart failure symptoms and valve haemodynamics in this cohort of Australian patients.[Abstract] [Full Text] [Related] [New Search]