These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Quantitative digital subtraction coronary angiography using videodensitometry. An in vivo analysis.
    Author: Simons MA, Muskett AD, Kruger RA, Klausner SC, Burton NA, Nelson JA.
    Journal: Invest Radiol; 1988 Feb; 23(2):98-106. PubMed ID: 3277924.
    Abstract:
    A videodensitometric method for measuring absolute cross-sectional area and diameter has been tested in living dogs with coronary artery stenoses created surgically by placement of small Silastic cuffs. Coronary arteriograms were performed using a circular tomographic unit to provide multiple views of each lesion, and measurements were made from logarithmically subtracted digital images. Dimensions of 13 stenoses of cross section 1 to 5 mm2 and adjacent reference segments (2 to 9 mm2) were determined by histologic sectioning of the segments after injection with a rapidly hardening plastic fixative under physiologic pressure. Two different methods were tested for calculating cross-sectional area. On 238 measurements, 102 of normal vessel segments and 135 of stenoses, both methods showed good correlation with histologic measurements, with slopes of 0.929 + (SD) 0.037 (r = 0.8563) and 0.948 + (SD) 0.037 (r = 0.8554). Multiple measurements of each segment produced values within 30% of the true absolute cross sectional area in most cases. The method shows promise as a means for quantitating absolute dimensions of vessels in clinical arteriography.
    [Abstract] [Full Text] [Related] [New Search]