These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Molecular Imprinting of Bisphenol A on Silica Skeleton and Gold Pinhole Surfaces in 2D Colloidal Inverse Opal through Thermal Graft Copolymerization.
    Author: Yang JC, Park J.
    Journal: Polymers (Basel); 2020 Aug 22; 12(9):. PubMed ID: 32842670.
    Abstract:
    This study successfully fabricated BPA-imprinted poly(4-vinylpyridine-co-ethylene glycol dimethacrylate) (poly(4-VP-co-EGDMA)) quartz crystal microbalance (MIP-QCM) sensors on a silica skeleton surface and gold pinholes of silica inverse opal through surface-initiated atom transfer radical polymerization (SI-ATRP). The sensing features of the two MIP films on the structured silica surface and nano-scale local gold surface were investigated by measuring the resonant frequency change (∆f) in QCM sensors. The ∆f values for the p-MIP (MIP on gold pinholes) and s-MIP films (MIP on silica skeleton surface) were obtained with the ∆f value of -199 ± 4.9 Hz and -376 ± 19.1 Hz, respectively, whereas for p-/s-NIP films, the ∆f values were observed to be -115 ± 19.2 Hz and -174 ± 5.8 Hz by the influence of non-specific adsorption on the surface of the films. Additionally, the imprinting factor (IF) appeared to be 1.72 for p-MIP film and 2.15 for s-MIP film, and the limits of quantitation (LOQ) and detection (LOD) were 54.924 and 18.125 nM (p-MIP film) and 38.419 and 12.678 nM (s-MIP film), respectively. Using the Freundlich isotherm model, the binding affinity of the BPA-imprinted films was evaluated. This was measured in an aqueous solution of BPA whose concentration ranged between 45 and 225 nM. It was found that the p-MIP film (m = 0.39) was relatively more heterogeneous than the s-MIP film (m = 0.33), both of which were obtained from the slope of the linear regressions. Finally, the selectivity of the MIP-QCM sensors for BPA detection was determined by measuring the effect of other analogous chemicals, such as bisphenol F (BPF), bisphenol AP (BPAP), and bisphenol B (BPB), in aqueous solutions. The selectivity coefficients (k*) of the two MIP films had ~1.9 for the p-MIP and ~2.3 for the s-MIP films, respectively. The results reveal that, with respect to signal amplification of the QCM sensors, the s-MIP film has better sensing features and faster detection responses than the p-MIP film.
    [Abstract] [Full Text] [Related] [New Search]