These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evaluation of ECG-gated and Fast Low-Angle Shot (FLASH) Dual Source Computed Tomography Scanning Protocols for Transcatheter Aortic Valve Replacement. Author: Qureshi WT, Malhotra R, Schmidlin EJ, Ahmed M, Kundu A, Hafiz AM, Walker J, Kakouros N. Journal: Acad Radiol; 2021 Dec; 28(12):1669-1674. PubMed ID: 32972842. Abstract: BACKGROUND: Transcatheter aortic valve replacement (TAVR) procedural success relies heavily on volumetric reconstruction imaging, particularly ECG-gated multi-detector row computed tomography. We postulated that single examination using fast low-angle shot (FLASH) dual source CT scanning (DS-CTA) could provide lower dose than ECG-gated CTA while maintaining the image quality. METHODS: In this single-centre cohort study, all patients who underwent ECG-gated and FLASH DS-CTA were evaluated. Volumetric reconstructions were performed for both ECG-gated and FLASH DS-CTA to obtain nonsagittal views of the structures. ECG-gated cardiac CT was obtained to evaluate the aortic annular size while FLASH DS-CTA was obtained to examine the aortic and iliac vasculature as part of TAVR imaging protocol. We evaluated measures of aortic annulus, coronaries and sinus of Valsalva using ECG-gated and FLASH DS-CTA scanning protocols. Image quality assessments were performed using aortic root region-of-interest signal-to-noise ratio. RESULTS: A total of 130 patients (mean age 81.5 ± 9.2 years, 46.2% female, and 99.2% white) underwent both ECG-gated CT and FLASH DS-CTA. There were excellent correlations between aortic annular area (R2 = 0.934) and aortic annular perimeter (R2 = 0.923) measured by the two protocols. Only 2 (1.5%) patients had >10% difference between aortic annular measurements by ECG-gated and FLASH DS-CTA, while none of the patients had a >10% difference between aortic annular perimeter measured by ECG-gated and FLASH DS-CT scans. There was no significant difference in signal-to-noise ratio between the two methods (mean difference 13.4; 95% CI -2.1-28.8, p = 0.09). There was significantly lower radiation dose for FLASH DS-CTA than ECG-gated CT scan (mean dose-length product difference 404.38; 95% CI 328.9-479.87, p <0.001). The measurements by the two scans led to the same transcatheter valve size selection in majority of the 128 (98.5%) patients by balloon expandable valve sizing recommendations and 130 (100%) of patients by self-expanding valve sizing recommendations. CONCLUSION: Overall, FLASH DS-CTA and ECG-gated CT scans provided comparable image quality and aortic annular dimensions for pre-TAVR evaluation. DS-CTA additionally provided the necessary angiographic imaging of the aorta and peripheral access vessels while still maintaining a lower radiation dose. We propose that a single non-ECG gated FLASH DS-CTA could be utilized to provide all the necessary pre-TAVR imaging information without a gated CT scan.[Abstract] [Full Text] [Related] [New Search]