These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Specific recognition of cationic paraquat in environmental water and vegetable samples by molecularly imprinted stir-bar sorptive extraction based on monohydroxylcucurbit[7]uril-paraquat inclusion complex. Author: Yao J, Zhang L, Ran J, Wang S, Dong N. Journal: Mikrochim Acta; 2020 Sep 25; 187(10):578. PubMed ID: 32975594. Abstract: Molecularly imprinted stir-bar coatings were created based on a hydroxylcucurbit[7]uril-paraquat inclusion complex. The inclusion complex that contained paraquat (PQ) as a template and monohydroxylcucurbit[7]uril ((OH)Q[7]) as a monomer was preassembled mainly through cavity inclusion interaction of (OH)Q[7] to form a one-dimensional self-assembly structure. The inclusion complex was anchored chemically on the surface of a glass stir bar with hydroxy-terminated poly(dimethylsiloxane) by the sol-gel technique to obtain a molecularly imprinted polymer-coated stir bar (MIP-SB). The molecularly imprinted coating showed specific adsorption for cationic PQ in aqueous media. Other quaternary amine compounds with a similar structure that coexisted in the solution, such as ethyl-viologen, diquat, and difenzoquat, were almost not extracted by the prepared MIP-SB. The sorptive capacity of the MIP-SB for PQ was nearly four times that of the non-imprinted stir bar (NIP-SB). The recognition mechanism indicated that the selectivity and extraction capacity resulted mainly from the imprinted cavity in the polymer that was formed by a one-dimensional assembly structure consisting of the (OH)Q[7]-PQ inclusion complex. The imprinted cavity was complementary to the PQ in shape, size, and functionality. A method to determine PQ in environmental water and vegetable samples was developed by combining MIP-SB sorptive extraction with HPLC-UV. The linear range was from 100 to 10,000 ng L-1 with a 8.2 ng L-1 detection limit for water samples and 0.02-0.85 mg kg-1 with a 0.005 mg kg-1 detection limit for vegetable samples. The limit of detection for both samples was lower than the EU-established maximum residual levels and that of other previously reported methods. The average recoveries were 70.0-96.1% with a relative standard deviation ≤ 7.6%, which showed the successful application in real sample analysis. Molecularly imprinted stir-bar coatings were created based on a hydroxylcucurbit[7]uril-paraquat (PQ) inclusion complex, which showed a specific recognition toward cationic PQ. A method to determine PQ in environmental water and vegetable samples was established by combining MIP-SB sorptive extraction with HPLC-UV.[Abstract] [Full Text] [Related] [New Search]