These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Influence of overdistension/recruitment induced by high positive end-expiratory pressure on ventilation-perfusion matching assessed by electrical impedance tomography with saline bolus. Author: He H, Chi Y, Long Y, Yuan S, Frerichs I, Möller K, Fu F, Zhao Z. Journal: Crit Care; 2020 Sep 29; 24(1):586. PubMed ID: 32993811. Abstract: BACKGROUND: High positive end-expiratory pressures (PEEP) may induce overdistension/recruitment and affect ventilation-perfusion matching (VQMatch) in mechanically ventilated patients. This study aimed to investigate the association between PEEP-induced lung overdistension/recruitment and VQMatch by electrical impedance tomography (EIT). METHODS: The study was conducted prospectively on 30 adult mechanically ventilated patients: 18/30 with ARDS and 12/30 with high risk for ARDS. EIT measurements were performed at zero end-expiratory pressures (ZEEP) and subsequently at high (12-15 cmH2O) PEEP. The number of overdistended pixels over the number of recruited pixels (O/R ratio) was calculated, and the patients were divided into low O/R (O/R ratio < 15%) and high O/R groups (O/R ratio ≥ 15%). The global inhomogeneity (GI) index was calculated to evaluate the ventilation distribution. Lung perfusion image was calculated from the EIT impedance-time curves caused by 10 ml 10% NaCl injection during a respiratory pause (> 8 s). DeadSpace%, Shunt%, and VQMatch% were calculated based on lung EIT perfusion and ventilation images. RESULTS: Increasing PEEP resulted in recruitment mainly in dorsal regions and overdistension mainly in ventral regions. ΔVQMatch% (VQMatch% at high PEEP minus that at ZEEP) was significantly correlated with recruited pixels (r = 0.468, P = 0.009), overdistended pixels (r = - 0.666, P < 0.001), O/R ratio (r = - 0.686, P < 0.001), and ΔSpO2 (r = 0.440, P = 0.015). Patients in the low O/R ratio group (14/30) had significantly higher Shunt% and lower VQMatch% than those in the high O/R ratio group (16/30) at ZEEP but not at high PEEP. Comparable DeadSpace% was found in both groups. A high PEEP caused a significant improvement of VQMatch%, DeadSpace%, Shunt%, and GI in the low O/R ratio group, but not in the high O/R ratio group. Using O/R ratio of 15% resulted in a sensitivity of 81% and a specificity of 100% for an increase of VQMatch% > 20% in response to high PEEP. CONCLUSIONS: Change of ventilation-perfusion matching was associated with regional overdistention and recruitment induced by PEEP. A low O/R ratio induced by high PEEP might indicate a more homogeneous ventilation and improvement of VQMatch. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04081155 . Registered on 9 September 2019-retrospectively registered.[Abstract] [Full Text] [Related] [New Search]