Title: Ultrasensitive determination of nitrite based on electrochemical platform of AuNPs deposited on PDDA-modified MXene nanosheets. Author: Wang Y, Zeng Z, Qiao J, Dong S, Liang Q, Shao S. Journal: Talanta; 2021 Jan 01; 221():121605. PubMed ID: 33076135. Abstract: An ultrasensitive and high-performance electrochemical nitrite sensing platform based on gold nanoparticles deposited on poly (dimethyl diallyl ammonium chloride)-decorated MXene (Ti3C2Tx) (AuNPs/Ti3C2Tx-PDDA) was constructed. AuNPs/Ti3C2Tx-PDDA on the surface of electrode displayed synergetic catalytic effect for oxidizing NO2‾ originating from especially catalytic activity of AuNPs, large area and excellent conductivity of Ti3C2Tx, as well as electrostatic interaction of PDDA. The amperometry technique was employed for quantitative determination of nitrite, in which the AuNPs/Ti3C2Tx-PDDA/GCE sensing platform showed outstanding linear relationship in 0.1-2490 μM and 2490-13490 μM for nitrite, meanwhile the detection limit of 0.059 μM. Besides, the prepared sensor possessed high sensitivity of 250 μA mM-1 cm-2 yet excellent selectivity, stability and reproducibility. Furthermore, this platform also exhibited satisfactory feasibility of nitrite sensing in running water and ham sausage sample. This work would broaden a facile approach to construct high sensitivity electrochemical sensing platform via two-dimension materials and its nanocomposites.[Abstract] [Full Text] [Related] [New Search]