These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Non-enhanced ultrasound is not a satisfactory modality for measuring necrotic ablated volume after radiofrequency ablation of benign thyroid nodules: a comparison with contrast-enhanced ultrasound. Author: Yan L, Luo Y, Xiao J, Lin L. Journal: Eur Radiol; 2021 May; 31(5):3226-3236. PubMed ID: 33128600. Abstract: OBJECTIVE: To investigate the intra- and inter-observer reliability and agreement between gray-scale and Doppler ultrasound (US) and contrast-enhanced ultrasound (CEUS) in measuring ablated volume (Va) after radiofrequency ablation (RFA) for benign thyroid nodules. METHODS: A total of 173 patients with 190 benign thyroid nodules who underwent RFA were included in this study. After RFA, the total volume of ablated nodule was divided into Va and the incompletely treated vital volume. Patients were followed up at 1, 3, 6, 12 months, and every 12 months thereafter. Two independent observers measured Va using US and CEUS during the same follow-up visit. The intra- and inter-observer reliability of the two measurement modalities was assessed using intraclass correlation coefficient (ICC) with 95% confidence interval. The Bland-Altman analysis was used to evaluate agreement, which was expressed as a mean difference with 95% limits of agreement (LOA). RESULTS: The mean follow-up time was 23.17 ± 12.70 months. Va measured by US was significantly larger than by CEUS (p < 0.001). The intra- and inter-observer reliability decreased over the follow-up period and became moderate in both subgroups at 12 months (all ICC < 0.75). The mean difference and LOA became larger and wider during the follow-up. The best agreement was found in nodules < 10 ml at 1 month with a mean difference of 1.166 and LOA between 0.413 and 3.294. CONCLUSIONS: The intra- and inter-observer reliability and agreement of US and CEUS in measuring Va were unsatisfactory. CEUS should be considered when Va was needed for further evaluation or in the case of nodules with suspected regrowth. KEY POINTS: • Va measured by gray-scale and Doppler US was significantly larger than that by CEUS. • Va measured by gray-scale and Doppler US lacked intra- and inter-observer reliability and agreement with CEUS. • CEUS should be preceded to gray-scale and Doppler US for the measurement of Va.[Abstract] [Full Text] [Related] [New Search]