  • Title: Sustained Improvement in Tracheal Intubation Safety Across a 15-Center Quality-Improvement Collaborative: An Interventional Study From the National Emergency Airway Registry for Children Investigators.
    Author: Nishisaki A, Lee A, Li S, Sanders RC, Brown CA, Rehder KJ, Napolitano N, Montgomery VL, Adu-Darko M, Bysani GK, Harwayne-Gidansky I, Howell JD, Nett S, Orioles A, Pinto M, Shenoi A, Tellez D, Kelly SP, Register M, Tarquinio K, Simon D, Krawiec C, Shults J, Nadkarni V, for National Emergency Airway Registry for Children (NEAR4KIDS) and Pediatric Acute Lung Injury and Sepsis Investigators (PALISI).
    Journal: Crit Care Med; 2021 Feb 01; 49(2):250-260. PubMed ID: 33177363.
    Abstract:
    OBJECTIVES: To evaluate the effect of a tracheal intubation safety bundle on adverse tracheal intubation-associated events across 15 PICUs. DESIGN: Multicenter time-series study. SETTING: PICUs in the United States. PATIENTS: All patients received tracheal intubations in ICUs. INTERVENTIONS: We implemented a tracheal intubation safety bundle as a quality-improvement intervention that includes: 1) quarterly site benchmark performance report and 2) airway safety checklists (preprocedure risk factor, approach, and role planning, preprocedure bedside "time-out," and immediate postprocedure debriefing). We define each quality-improvement phase as baseline (-24 to -12 mo before checklist implementation), benchmark performance reporting only (-12 to 0 mo before checklist implementation), implementation (checklist implementation start to time achieving > 80% bundle adherence), early bundle adherence (0-12 mo), and sustained (late) bundle adherence (12-24 mo). Bundle adherence was defined a priori as greater than 80% of checklist use for tracheal intubations for 3 consecutive months. MEASUREMENTS AND MAIN RESULTS: The primary outcome was the adverse tracheal intubation-associated event, and secondary outcomes included severe tracheal intubation-associated events, multiple tracheal intubation attempts, and hypoxemia less than 80%.From January 2013 to December 2015, out of 19 participating PICUs, 15 ICUs (79%) achieved bundle adherence. Among the 15 ICUs, the adverse tracheal intubation-associated event rates were baseline phase: 217/1,241 (17.5%), benchmark reporting only phase: 257/1,750 (14.7%), early 0-12 month complete bundle compliance phase: 247/1,591 (15.5%), and late 12-24 month complete bundle compliance phase: 137/1,002 (13.7%). After adjusting for patient characteristics and clustering by site, the adverse tracheal intubation-associated event rate significantly decreased compared with baseline: benchmark: odds ratio, 0.83 (0.72-0.97; p = 0.016); early bundle: odds ratio, 0.80 (0.63-1.02; p = 0.074); and late bundle odds ratio, 0.63 (0.47-0.83; p = 0.001). CONCLUSIONS: Effective implementation of a quality-improvement bundle was associated with a decrease in the adverse tracheal intubation-associated event that was sustained for 24 months.
    [Abstract] [Full Text] [Related] [New Search]