These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of Biodosimetry Biomarkers for Radiation Dose and Injury Assessment After Mixed-Field (Neutron and Gamma) and Pure Gamma Radiation in the Mouse Total-Body Irradiation Model. Author: Ossetrova NI, Stanton P, Krasnopolsky K, Ismail M, Doreswamy A, Hieber KP. Journal: Health Phys; 2018 Dec; 115(6):743-759. PubMed ID: 33289997. Abstract: The detonation of a nuclear weapon and the occurrence of a nuclear accident represent possible mass-casualty events with significant exposure to mixed neutron and gamma radiation fields in the first few minutes after the event with the ensuing fallout, extending for miles from the epicenter, that would result primarily in photon (gamma- and/or x-ray) exposure. Circulating biomarkers represent a crucial source of information in a mass-casualty radiation exposure triage scenario. We evaluated multiple blood biodosimetry and organ-specific biomarkers for early-response assessment of radiation exposure using a mouse (B6D2F1, males and females) total-body irradiation model exposed to Co gamma rays over a broad dose range (3-12 Gy) and dose rates of either 0.6 or 1.9 Gy min and compared the results with those obtained after exposure of mice to a mixed field (neutrons and gamma rays) using the Armed Forces Radiobiology Research Institute Co gamma-ray source and TRIGA Mark F nuclear research reactor. The mixed-field studies were performed previously over a broad dose range (1.5-6 Gy), with dose rates of either 0.6 or 1.9 Gy min, and using different proportions of neutrons and gammas: either (67% neutrons + 33% gammas) or (30% neutrons + 70% gammas). Blood was collected 1, 2, 4, and 7 d after total-body irradiation. Results from Co gamma-ray studies demonstrate: (1) significant dose- and time-dependent reductions in circulating mature hematopoietic cells; (2) dose- and time-dependent changes in fms-related tyrosine kinase 3 ligand, interleukins IL-5, IL-10, IL-12, and IL-18, granulocyte colony-stimulating factors, thrombopoietin, erythropoietin, acute-phase proteins (serum amyloid A and lipopolysaccharide binding protein), surface plasma neutrophil (CD45) and lymphocyte (CD27) markers, ratio of CD45 to CD27, procalcitonin but not in intestinal fatty acid binding protein; (3) no significant differences were observed between dose-rate groups in hematological and protein profiles (fms-related tyrosine kinase 3 ligand, IL-5, IL-12, IL-18, erythropoietin, granulocyte colony-stimulating factor, granulocyte-macrophage colony-stimulating factor, CD27, CD45, and ratio of CD45 to CD27) for any radiation dose at any time after exposure (p > 0.148); (4) no significant differences were observed between sex groups in hematological and protein profiles (fms-related tyrosine kinase 3 ligand, IL-18, erythropoietin, granulocyte colony-stimulating factor, granulocyte-macrophage colony-stimulating factor, serum amyloid A, CD45) for any radiation dose at any time after exposure (p > 0.114); and (5) PCT level significantly increased (p < 0.008) in mice irradiated with 12 Gy on day 7 post-total-body irradiation without significant differences between groups irradiated at dose rates of either 0.6 or 1.9 Gy min (p > 0.287). Radiation-quality comparison results demonstrate that: (1) equivalent doses of pure gamma rays and mixed-field radiation do not produce equivalent biological effects, and hematopoietic syndrome occurs at lower doses of mixed-field radiation; (2) ratios of hematological and protein biomarker means in the Co study compared to mixed-field studies using 2× Co doses vs. 1× TRIGA radiation doses (i.e., 3 Gy Co vs. 1.5 Gy TRIGA) ranged from roughly 0.2 to as high as 26.5 but 57% of all ratios fell within 0.7 and 1.3; and (3) in general, biomarker results are in agreement with the relative biological effectiveness = 1.95 (Dn/Dt = 0.67) reported earlier by Armed Forces Radiobiology Research Institute scientists in mouse survival countermeasure studies.[Abstract] [Full Text] [Related] [New Search]