These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Flow Diverter Apposition in Patients with Large or Giant Intracranial Aneurysms Evaluated on Three-Dimensional Fusion Images Acquired by High-Resolution Cone-Beam Computed Tomography and Digital Subtraction Angiography. Author: Kato N, Yuki I, Otani K, Ishibashi T, Kakizaki S, Nagayama G, Maruyama F, Ikemura A, Kan I, Kodama T, Abe Y, Murayama Y. Journal: World Neurosurg; 2021 Mar; 147():e388-e395. PubMed ID: 33359518. Abstract: OBJECTIVE: To investigate flow diverter (FD) apposition on fused images acquired by high-resolution cone-beam computed tomography (CBCT) and 3-dimensional (3D) digital subtraction angiography. METHODS: Patients with large or giant internal carotid artery aneurysms treated with Pipeline FDs who underwent CBCT imaging at our institution between October 2016 and May 2019 were included. Two neurosurgeons measured the maximum malapposition between FDs and vessel walls on 3D fusion images of high-resolution CBCT images displaying the FD and 3D digital subtraction angiography images displaying the vessels. Associations between the relative malapposition, FD diameter, vessel diameter, proximal and distal vessel diameter discrepancy, and siphon angle were evaluated by linear regression analysis. Inter-rater and intermethod (3D and 2D image) agreements of the malapposition measurements were assessed by Bland-Altman analysis and by interclass correlation coefficients. RESULTS: Images of 2 patients were excluded because of image artifacts or fusion errors, and 3D fusion images were acquired in the remaining 26 patients. Our results did not suggest that relative malapposition was associated with vessel diameter (P = 0.12), vessel diameter discrepancy (P = 0.60), or syphon angle (P = 0.34), but relative malapposition increased by an estimated 13% (95% confidence interval: 4%-23%, P = 0.006) for each 1 mm increase in FD diameter. Inter-rater and intermethod agreements for apposition measurements were excellent and good, respectively. CONCLUSIONS: Three-dimensional fusion images provided clear visualization of structures of both the stent and parent artery with excellent diagnostic reliability. Careful deployment may be needed for FDs with larger diameters, as they tended to have larger relative malapposition.[Abstract] [Full Text] [Related] [New Search]