These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Physiological parameters of indicator dilution curves. Author: Homer LD, Small A. Journal: Am J Physiol; 1977 Sep; 233(3):H350-5. PubMed ID: 333944. Abstract: A model incorporating the effects of recirculation time lag, cardiac output, clearance, volume of distribution, and the variance of the distribution of recirculation times is applied to the analysis of indicator dilution curves. Experiments on dogs with use of radioactively labeled diethylenetriaminepentaacetic acid were done to evaluate the model. This five-parameter model can be fitted to data obtained during the period from less than 1 min to 3 h after a single injection of indicator. Estimates of cardiac output and clearance are in satisfactory agreement with estimates obtained by alternative techniques. Estimates of the time lag and volume of distribution are of physiologically plausible magnitude. The variance of the distribution of recirculation times is a new parameter, of which the possible usefulness to physiologists is discussed.[Abstract] [Full Text] [Related] [New Search]