  • Title: Intensity-time tradeoff for constant hearing loss with high sound levels.
    Author: Oftedal G, Nivison ME, Jinze Z.
    Journal: J Acoust Soc Am; 1988 Jan; 83(1):203-11. PubMed ID: 3343440.
    Abstract:
    The tradeoff relation between exposure intensity and duration for constant hearing loss was investigated in two series of experiments using Mongolian gerbils. The gerbils were exposed to a 1/3 octave band of noise at 2.5 kHz. In the first series animals were exposed to 120 dB SPL for 1 h, to 126 dB SPL for 15 min, and to 126 dB SPL for 3.75 min. In the second series, shorter durations were used: 120 dB SPL for 15 min, 126 dB SPL for 3.75 min, and 126 dB SPL for 56 s. The hearing thresholds were determined behaviorally immediately before exposure and 6 weeks after exposure. The results suggest that the intensity-time tradeoff for the investigated intensity interval is between 1.5 and 3 dB per halving of the duration.