These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Impact of EBUS-TBNA in addition to [18F]FDG-PET/CT imaging on target volume definition for radiochemotherapy in stage III NSCLC. Author: Guberina M, Darwiche K, Hautzel H, Ploenes T, Pöttgen C, Guberina N, Herrmann K, Umutlu L, Wetter A, Theegarten D, Aigner C, Eberhardt WEE, Schuler M, Karpf-Wissel R, Stuschke M. Journal: Eur J Nucl Med Mol Imaging; 2021 Aug; 48(9):2894-2903. PubMed ID: 33547554. Abstract: UNLABELLED: PURPOSE/INTRODUCTION: [18F]FDG-PET/CT is the standard imaging-technique for radiation treatment (RT) planning in locally advanced non-small cell lung cancer (NSCLC). The purpose of this study was to examine the additional value of endobronchial-ultrasound transbronchial needle aspiration (EBUS-TBNA) to standard PET/CT for mediastinal lymph-node (LN) staging and its impact on clinical target volume (CTV). MATERIALS AND METHODS: All consecutive patients with primary stage III NSCLC who underwent [18F]FDG-PET/CT and EBUS-TBNA prior to RT were analyzed from 12/2011 to 06/2018. LN-stations were assessed by an expert-radiologist and a nuclear medicine-physician. CTV was evaluated by two independent radiation oncologists. LNs were grouped with increasing distance along the lymphatic chains from primary tumor into echelon-1 (ipsilateral hilum), echelon-2 (LN-station 7 and ipsilateral 4), and echelon-3 (remaining mediastinum and contralateral hilum). RESULTS: A total of 675 LN-stations of which 291 were positive for tumor-cells, were sampled by EBUS-TBNA in 180 patients. The rate of EBUS-positive LNs was 43% among all sampled LNs. EBUS-positivity in EBUS-probed LNs decreased from 85.8% in echelon-1 LNs to 42.4%/ 9.6% in echelon-2/ -3 LNs, respectively (p < 0.0001, Fisher's exact test). The false discovery rate of PET in comparison with EBUS results rose from 5.3% in echelon-1 to 32.9%/ 69.1% in echelon-2/ -3 LNs, respectively (p < 0.0001, Fisher's exact test). Sensitivity and specificity of FDG-PET/CT ranged from 85 to 99% and 67 to 80% for the different echelons. In 22.2% patients, EBUS-TBNA finding triggered changes of the treated CTV, compared with contouring algorithms based on FDG-avidity as the sole criterion for inclusion. CTV was enlarged in 6.7% patients due to EBUS-positivity in PET-negative LN-station and reduced in 15.5% by exclusion of an EBUS-negative but PET-positive LN-station. CONCLUSION: The false discovery rate of [18F]FDG-PET/CT increased markedly with distance from the primary tumor. Inclusion of systematic mediastinal LN mapping by EBUS-TBNA in addition to PET/CT has the potential to increase accuracy of target volume definition, particularly in echelon-3 LNs. EBUS-TBNA is recommended as integral part of staging for radiochemotherapy in stage III NSCLC.[Abstract] [Full Text] [Related] [New Search]