These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Carbon cloth-supported nanorod-like conductive Ni/Co bimetal MOF: A stable and high-performance enzyme-free electrochemical sensor for determination of glucose in serum and beverage.
    Author: Xu Z, Wang Q, Zhangsun H, Zhao S, Zhao Y, Wang L.
    Journal: Food Chem; 2021 Jul 01; 349():129202. PubMed ID: 33582540.
    Abstract:
    In this work, we propose a electrochemical enzyme-free glucose sensor by direct growth of conductive Ni/Co bimetal MOF on carbon cloth [Ni/Co(HHTP)MOF/CC] via a facile hydrothermal method. Due to excellent conductivity between Ni/Co(HHTP)MOF and CC, synergic catalytic effect of Ni and Co elements, the Ni/Co(HHTP)MOF/CC not only provides larger surface area and more effective active sites, but also boosts the charge transports and electro-catalytic performance. Under optimized conditions, the Ni/Co(HHTP)MOF/CC shows excellent activity with a linear range of 0.3 μM-2.312 mM, a low detection limit of 100 nM (S/N = 3), a fast response time of 2 s and a high sensitivity of 3250 μA mM-1 cm-2. Furthermore, the Ni/Co(HHTP)MOF/CC was successfully applied for the detection of glucose in real serum and beverages with competitive performances. This facile and cost-effective method provides a novel strategy for monitoring of glucose in biological and food samples.
    [Abstract] [Full Text] [Related] [New Search]