These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Infants with pulmonary atresia intact ventricular septum who require balloon atrial septostomy have significantly higher 18-month mortality. Author: Herrick NL, Courelli A, Lee JW, Ratnayaka K, Alshawabkeh LI, Moore JW, El-Said HG. Journal: Cardiol Young; 2021 Oct; 31(10):1613-1618. PubMed ID: 33641693. Abstract: INTRODUCTION: Many newborns with pulmonary atresia/intact ventricular septum require intervention to establish pulmonary flow and sufficient cardiac output. The resulting haemodynamic changes are not well characterised and may have unintended consequences. METHODS: This is a 30-year (1988-2018) retrospective study of patients with pulmonary atresia intact ventricular septum. RESULTS: Eighty-nine patients were included, and median follow-up was 8 years. Fifty-five per cent had coronary sinusoids and 27% had right ventricular-dependent coronary circulation. Most patients were managed with surgical aortopulmonary or modified Blalock-Taussig shunt (73%), and 12 patients underwent balloon atrial septostomy before surgical intervention. The remaining patients (27%) underwent only transcatheter interventions; 7 required an atrial septostomy and 17 required ductal stentings. All-cause mortality was 10%, most deaths (89%) occurred before 18 months of age. Of these early deaths, 87% required a balloon atrial septostomy and 85% had right ventricular-dependent coronary sinusoids. Eighteen-month mortality was significantly higher for patients who required a balloon atrial septostomy compared to those who did not (36% versus 1.4% p < 0.0001). DISCUSSION: Patients with pulmonary atresia/intact ventricular septum who require balloon atrial septostomy in the newborn period have significantly higher 18-month mortality. Quantifying the mortality difference may help guide prognostication and expectation setting. Infants who had septostomy and a surgical shunt in the newborn period fared better than those who only underwent septostomy (even when accompanied by ductal stenting). For infants with right ventricular-dependent circulation, atrial septostomy should only be performed on an urgent or emergent basis and these patients should be considered for early surgical intervention and neonatal transplant.[Abstract] [Full Text] [Related] [New Search]