These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Reappraisal of atrioventricular junctional pacemaker automaticity in the sick sinus syndrome. Clinical significance and the role of autonomic chronotropic influences. Author: Chen JH, Lien WP, Chen JJ, Lin JL, Peng HC. Journal: Chest; 1988 Jun; 93(6):1170-5. PubMed ID: 3371095. Abstract: Postpacing impulse recovery times of the junctional tissue (junctional automaticity) were determined by atrial or ventricular overdrive pacing in 27 patients with dysfunction of the sinus node. The maximum junctional recovery time (MJRT) could be measured in 22 patients and ranged from 1,630 to 9,730 ms (mean 3,860 +/- 2,077); the maximum corrected junctional recovery time (MJRTc) could be measured in 18 patients and ranged from 140 to 5,986 ms (mean 2,089 +/- 1,529). Autonomic influence on the JRTs was evaluated by intravenous administration of atropine (1.5 mg) alone or in combination with propranolol (5 to 6 mg). Of the seven patients in whom MJRTc and/or MJRT could be measured before and after drug intervention, the JRTs shortened in four and prolonged in three after combination of atropine and propranolol. Atropine alone shortened MJRT in all eight patients studied. Our data reveal that both vagal and catecholamine-dependent factors (especially vagal over-activity) are operative in the escape mechanism of the junctional tissue.[Abstract] [Full Text] [Related] [New Search]