These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Rapid rotational magneto-acousto-electrical tomography with filtered back-projection algorithm based on plane waves. Author: Sun T, Hao P, Chin CT, Deng D, Chen T, Chen Y, Chen M, Lin H, Lu M, Gao Y, Chen S, Chang C, Chen X. Journal: Phys Med Biol; 2021 Apr 21; 66(9):. PubMed ID: 33725674. Abstract: Magneto-acousto-electrical tomography (MAET) is designed to produce conductivity images with high spatial resolution for a conducting object. In a previous study, for an irregular conductor, transverse scanning and rotational methods with a focus transducer were combined to collect complete electrical information. This kind of method, however, is time-consuming because of the transverse scanning procedure. In this study, we proposed a novel imaging method based on plane ultrasound waves and a new aspect of projection in rotational MAET. In the proposed method, we achieved the projection in each rotation angle by using plane waves rather than mechanical scanning of the focus waves along the transverse direction. Thus, the imaging time was significantly saved. To verify the proposed method, we derived a measurement formula containing a lateral integration, which built the relationship between the measurement formula and the projection under each rotation angle. Next, we constructed two different numerical models to compute magneto-acousto-electrical signals by using a finite element method and reconstructed the corresponding conductivity parameter images based on a filtered back-projection algorithm. Then, simulated signals under different signal-to-ratios (6, 20, 40, and 60 dB) were generated to test the performance of the proposed algorithm. To improve the image quality, we further analysed the influence of the filters and the frequency scaling factors embedded in the filtered back-projection algorithm. Moreover, we computed the L2norm of the error in case of different frequency scaling factors and measurement noises. Finally, we conducted a phantom experiment with a 64-element linear phased array transducer (center frequency of 2.7 MHz) and reconstructed the conductivity parameter images of the circular phantom with an elliptical hole. The experimental results demonstrated the feasibility and time-efficiency of the proposed rapid rotational MAET.[Abstract] [Full Text] [Related] [New Search]