These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A Normal Electrocardiogram Does Not Exclude Infra-Hisian Conduction Disease in Patients With Myotonic Dystrophy Type 1. Author: Creta A, Providência R, Gossios T, Elliott PM, Turner C, Savvatis K, Segal OR. Journal: JACC Clin Electrophysiol; 2021 Aug; 7(8):1038-1048. PubMed ID: 33812832. Abstract: OBJECTIVES: This study aimed to identify electrocardiographic (ECG) predictors of a prolonged His-ventricular (HV) interval in patients with type 1 myotonic dystrophy (DM1). BACKGROUND: Patients with DM1 have an increased risk of sudden cardiac death. The presence of His-Purkinje system disease/prolonged HV interval (≥70 ms) is associated with a higher risk of potentially life-threatening bradyarrhythmic events. METHODS: Electrophysiology studies (EPSs) were performed in all DM1 patients referred to 2 tertiary centers for routine cardiac assessment. In a subgroup of patients, the EPS was repeated at varying intervals. RESULTS: A total of 154 patients (mean age: 43.7 ± 13.3; 58.1% male) underwent 202 diagnostic EPSs. HV ≥70 ms was found on 58 EPSs (28.7%); 9 of 59 patients (15.2%) with PR <200 ms and QRS interval <110 ms on baseline ECG had an HV ≥70 ms on EPS. Among those with PR ≥200 ms and/or QRS interval ≥100 ms, only 33.9% had an HV ≥70 ms on EPS. There were 38 patients who underwent repeated EPS, in which 28.8% demonstrated a prolongation of the HV interval overall compared with baseline. QRS duration demonstrated the most powerful discriminative capacity for HV ≥70 ms (area under the receiver operating characteristic curve: 0.76; 95% confidence interval [CI]: 0.68 to 0.84; p < 0.001). On multivariate analysis, QRS interval ≥112 ms had the highest predictive value for HV ≥70 ms (odds ratio: 7.94; 95% CI: 3.85 to 16.37. CONCLUSIONS: ECG parameters have a poor predictive value for infra-Hisian conduction block in DM1 patients. QRS and PR intervals are normal in up to 15.2% of DM1 patients with prolonged HV, and 66.1% of those with PR ≥200 ms and/or QRS ≥100 ms do not have advanced His-Purkinje conduction system disease on EPS. Electrophysiology testing should be a mandatory part of screening for all patients to guide prophylactic pacemaker implantation.[Abstract] [Full Text] [Related] [New Search]