These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Mass-Casualty Training Exercise Using High-Fidelity Computerized Simulators and Involving Time and Resource Limitation. Author: Jacobson PA, Severin PN, Rumoro DP, Shah S. Journal: Prehosp Disaster Med; 2021 Jun; 36(3):313-320. PubMed ID: 33845939. Abstract: PURPOSE: Training emergency department (ED) personnel in the care of victims of mass-casualty incidents (MCIs) is a highly challenging task requiring unique and innovative approaches. The purpose of this study was to retrospectively explore the value of high-fidelity simulators in an exercise that incorporates time and resource limitation as an optimal method of training health care personnel in mass-casualty care. METHODS: Mass-casualty injury patterns from an explosive blast event were simulated for 12 victims using high-fidelity computerized simulators (HFCS). Programmed outcomes, based on the nature of injuries and conduct of participants, ranged from successful resuscitation and survival to death. The training exercise was conducted five times with different teams of health care personnel (n = 42). The exercise involved limited time and resources such as blood, ventilators, and imaging capability. Medical team performance was observed and recorded. Following the exercise, participants completed a survey regarding their training satisfaction, quality of the exercise, and their prior experiences with MCI simulations. The Likert scale responses from the survey were evaluated using mean with 95% confidence interval, as well as median and inter-quartile range. For the categorical responses, the frequency, proportions, and associated 95% confidence interval were calculated. RESULTS: The mean rating on the quality of experiences related trainee survey questions (n = 42) was between 4.1 and 4.6 on a scale of 5.0. The mean ratings on a scale of 10.0 for quality, usefulness, and pertinence of the program were 9.2, 9.5, and 9.5, respectfully. One hundred percent of respondents believed that this type of exercise should be required for MCI training and would recommend this exercise to colleagues. The five medical team (n = 5) performances resulted in the number of deaths ranging from two (including the expectant victims) to six. Eighty percent of medical teams attempted to resuscitate the "expectant" infant and exhausted the O- blood supply. Sixty percent of medical teams depleted the supply of ventilators. Forty percent of medical teams treated "delayed" victims too early. CONCLUSION: A training exercise using HFCS for mass casualties and employing limited time and resources is described. This exercise is a preferred method of training among participating health care personnel.[Abstract] [Full Text] [Related] [New Search]